(L)VRCTL(R)8*1D, *2C, *3C VRCDTL(R)*C (L)VRCTL(R)DD*C
Page 2
98958C (Rev. B - 2/13)
F
D
F
E
E
2 7/
16
"
63
m
m
10
"
254
m
m
5" 127
m
m
1 1/2
"
38
m
m
A
37
1/2"
95
2m
m
6 1/2" 166m
m
O
RIF
IC
E
HE
IG
HT
AL
TU
RA
D
EL
ORIF
IC
IO
HA
U
TE
U
R D
E
L'
O
RI
FI
C
E
ORIF
IC
E
HEI
GHT
AL
TU
RA
D
EL
O
RIF
IC
IO
HA
UT
EU
R D
E
L'
O
RIF
IC
E
C L
C L
1 3
/8
"
35m
m
1 3
/8
"
35
mm
5 3/4" 14
6m
m
5 3/4" 146
m
m
1 3/8" 35
m
m
1 3
/8
"
35m
m
5 3/
4"
146m
m
5 3
/4"
146m
m
18
1/
16
"
45
9m
m
FI
NI
SH
ED
F
LOO
R
PI
SO
ACAB
AD
O
PL
AN
CH
ER F
IN
I
5/16"
(8m
m
) D
IA. (
10 HO
LE
S)
8m
m (10
AG
U
JER
O
U
S)
8m
m
(10
T
RO
U
S)
20 1/
8"
511
m
m
4 1/2" 11
4m
m
6 1
/4
"
159
m
m
18 3/
4"
476
m
m
25
1/8"
63
8m
m
B
3 1/2" 89m
m
C
RI
M
HE
IG
HT
AL
TU
RA
D
EL
O
RIF
IC
IO
HA
U
TE
U
R D
E
L '
OR
IFI
CE
18
5/
8"
47
4m
m
12
5/1
6"
31
2m
m
4 3
/4"
121
m
m
27
"
68
6m
m
31 7
/8"
810m
m
32
15/16"
83
7m
m
39
1
/2
"
1003m
m
2 5/8" 67
m
m
8" 203m
m
13 7
/8"
35
1m
m
20 3/8" 51
8m
m
HA
NG
ER
B
RA
CK
ET
FI
JA
DO
R D
E
SU
SP
EN
SIO
N
SU
PP
OR
T D
E
SU
SP
EN
SIO
N
*
6 3/4" 17
3m
m
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM
OUT FROM WALL
La UBICACION 3/8 O RECOMENDADA de ABASTECIMIENTO DE AGUA. D. El TUBO del COBRE de UNPLATED CONECTA TALONARIO CON APAGO (POR OT
ROS) 3 en. (76 Mm) el MAXIMO
FUERA DE PARED
L’O.D de 3/8 d’EMPLACEMENT DE PROVISION D’EAU RECOMMANDE. LE TUBE DE CUIVRE DE UNPLATED CONNECTE STUB AVEC ETEINT (PAR L
ES AUTRES) 3 dans. (76 mm) le MAXIMUM
HORS DU MUR
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2 IN. OUT FROM WALL
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/2” DE DIÁMETRO. El TALONARIO 2 FUERA DE PARED
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2" DE SORTIE D’EAU.
STUB 2 HORS DU MUR
C = 1-1/2 TRAP NOT FURNISHED
PURGADOR DE 1-1/2 NO PROPORCIONADO
SIPHON 1-1/2 NON FOURNI
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
CAJA RECESIVA DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTATION ÉLECTRIQUE (3) FILS
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6" (152
mm
) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUE
BLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6" (152
mm
) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE MUR.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJETAR LA UNIDAD A LA PARED
TROUS D’ÉCROUS 7/16 POUR FIXER L’APPAREIL AU MUR
FIG. 2
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
* * *
ADA REQUIREMENT
REQUISITO DE A.D.A.
EXIGENCE ADA
VRCTL8