75.0047.01 LZR-WIDESCAN Mechanical Installation 20210726
Page 2 of 12
Technology
LASER scanner, time-of-flight measurement (7 laser curtains)
Detection mode
Motion, presence, height, and speed
Max. detection field
Width: 1.2 × mounting height
Depth: 1.2 × mounting height
adjustable, depending on user settings
Thickness of first curtain
1
⁄
4
inch
Typ. mounting height
6’6” – 32’
Min. reflectivity factor
> 2 % (of floor and object) (measured at max. 19’6” in safety field)
Typ. min. object size
6” @ 19’6“ (in proportion to object distance)
Testbody
27
1
⁄
2
” × 11
3
⁄
4
”× 7
3
⁄
4
”
Emission characteristics
IR laser:
Red visible laser:
wavelength 905 nm; output power 0.10mW (CLASS 1)
wavelength 635 nm; output power 0.95mW (CLASS 2)
Supply voltage
12 – 24 VAC -10/+20% 12 – 30 VDC ±10% @ sensor terminal
Power consumption
< 2.5 W (heating: off) < 10 W, max 15 W (heating: eco or auto)
Response time
Typ. 230 ms; max. 800 ms (depending on immunity settings)
Output
2 solid-state relays ( galvanic isolation, polarity free )
24 VAC / 30 VDC (max. switching voltage) – 100 mA (max. switching current)
- in switching mode: NO/NC
- in frequency mode: pulsed signal (f= 100 Hz ±10%)
1 electro-mechanic relay (galvanic isolation, polarity free)
42 VAC/VDC (max. switching voltage) – 500 mA (max. switching current)
Input
30 VDC (max. switching voltage)
low < 1 V high > 10 V (voltage threshold)
LED signals
2 tri-colored LED: Output status / remote control response / error signals
1 blue LED: bluetooth status
Dimensions
7
3
⁄
4
” (H) x 6” (W) x 4” (D) (approx.)
Material / Color
PC/ASA / Black
Rotation angles on bracket
45° to the right, 15° to the left ( lockable )
Tilt angles on bracket
-10 – 5°
Protection degree
NEMA 4 / IP65
Temperature range
-22 – 140 °F
Norm conformity
IEC 61000-6-2
IEC 61000-6-3
IEC 60950-1
IEC 60825-1
ISO 13849-1 Pl “d”/ CAT2
IEC 62061 SIL 2
Specifications are subject
to change without
prior notice. All values
measured in specific
conditions.
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA,
Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/
device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294,
UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
TECHNICAL SPECIFICATIONS