75.0047.01 LZR-WIDESCAN Mechanical Installation 20210726
Page 10 of 12
1
E1
E1: CPU-XXX
The sensor encounters an internal
problem
Replace sensor.
2
E2
E2: XXX PWR
The internal power supply is faulty
Verify that you are using the correct power supply. Replace sensor, if
necessary.
E2: IN SUPPLY
The power supply is too low or too high
Verify power supply (Diagnostics > LCD).
E2: TEMP
The internal temperature is too low or
too high
Verify the sensor temperature (Diagnostics >LCD).
Protect the sensor from direct exposure to heat or cold.
6
E6
E6: FQ OUT
Faulty sensor output 1
Replace sensor.
8
E8
E8: ...
Faulty detection engine
If internal temperature is lower than 68 °F, wait until the heating
process is completed.
If temperature is higher than -4 °F, replace the sensor.
ORANGE LED is on
The sensor encounters a memory
problem
Replace sensor.
No power at startup
Incorrect wiring
Check connections at box and at the sensor.
Faulty sensor or harness
Try connection with a different known, good sensor. If still no power
at startup, try using a different known, good harness.
Sensor does not react to
remote control
Sensor is password-protected
Enter correct password. If you forgot the code, cut and restore power
supply in order to access the sensor without entering a password
during 1 minute.
Bad remote / Bad batteries
Check batteries in remote. Replace remote, if necessary.
Too far away from sensor
Stand directly underneath the LZR-WIDESCAN and point remote at
bottom of LED window.
Red spots turned on, but
not visible on ground
Sensor is obstructed
Use BEA brackets to extend the sensor past the obstructions.
Change the mounting location (left, right, center) to avoid the
obstruction.
Environmental conditions are too bright
Use a piece of white paper to locate spots.
Sensor won't adjust far
enough on the bracket
to center lasers over
opening
Bracket installation position
Try rotating the bracket clockwise to allow for more rotation.
Center of opening is too far away
Re-position sensor on bracket.
Visible spots won't
position correctly
Sensor is obstructed
Ensure there is nothing obstructing the visible spots.
Sensor is too far away from center of
entrance
Make adjustments to the three adjustment screws. If still unable to
position spots, the sensor location may need changed.
Lateral angle too extreme
Make adjustments to the lateral angle. If still unable to position spots,
the sensor location may need changed.
Cover opens
Cover is not locked
Close cover and lock.
Environmental issues
Check for ice. If present, use the heating function, if possible.