Scrubmaster B400 R (7190)
115
Maintenance and servicing
5.2.3
Checking the acid level
The customer must check the acid level of the batteries once a week.
Checking the acid level:
If the trough battery is equipped with an aquamatic system
Fig. 35-2
, each
individual cell features a sealing plug with float indicator.
The white dot must be located at the top and must be clearly visible. If this is
not the case, refill demineralised water according to DIN 43530-4.
Topping up with demineralised water:
Connect the end piece of the aquamatic system
Fig. 35-3
to a container with
demineralised water. Observe sufficient gradient, ensuring the water can flow
into the cells. Once the required filling level has been reached, the plugs auto-
matically seal the cells and indicate full
Fig. 35-1
.
Danger
Risk of explosion and fire! When handling batteries, it is prohibited to
smoke and use an open fire.
Attention
Observe the information in the operating manual of the battery
manufacturer!
Refilling must only take place once the battery charging process
has been terminated.
Note
Batteries approved by Hako are equipped with an aquamatic
system.
1
Float indicator
2
Aquamatic system
3
End piece of aquamatic system
Fig. 35
2
3
1
Содержание Scrubmaster B400 R
Страница 1: ...Scrubmaster B400 R RM RH 7190 Operating manual Part number 88 10 3255 Valid as from 03 2021...
Страница 9: ...Scrubmaster B400 R 7190 9...
Страница 26: ...26 Scrubmaster B400 R 7190 Safety instructions K J Fig 2 L J M A O N Q M K N P O 1 2 3 P Q L C...
Страница 30: ...30 Scrubmaster B400 R 7190 Use 2 1 2 Front view B400 RM 16 2 1 7 Fig 4 13 14 11 5 10 6 4 3 19 12 17 18 8 9 15...
Страница 158: ...158 Scrubmaster B400 R 7190 Attachments options Fig 67 5 6 3 2 4 1 3 12 9 10 11 1 4 7 8...
Страница 170: ...Hako GmbH Head Office Hamburger Str 209 239 23843 Bad Oldesloe Germany Tel 49 4531 806 0 info hako com www hako com...