55
1.1. Summary of technical specification
QUALITY CERTIFICATE – TECHNICAL SPECIFICATIONS Table 1.1.-1
Type
HPT200
HPT200C
Dimensions: diameter/height/depth
Ø667/1480/720
Water connection
G3/4
Rated volume
194 l
182 l
Rated operating pressure
0,6 MPa
Safety valve max. opening pressure
0,7 MPa
Highest water supply pressure
0,525 MPa
Lowest required network pressure
0,01 MPa
Standby energy use at 60 °C
580 Wh/24h
Weight
108 kg
125 kg
Pipe coil
Pipe coil connection
—
Rp3/4
Pipe coil heatable volume
—
12 l
Pipe coil surface
—
1,5 m
2
Highest medium temperature
—
90 °C
Highest medium pressure
—
0,2 MPa
Continuous performance
—
1100 l/h
Continuous power
—
45 kW
Heat pump
Type
air (indoor)
Ventilation duct connection (inlet/outlet)
Ø160 mm
Condenser
safety heat exchanger
GWP / Cooling agent / quantity
1300 g / R134a
Max. Power Consumption
515 W
Air flow
450 m
3
/h
Available static pressure (air)
50 Pa
External static pressure range where the appliance has been tested
1013–1050 hPa
Max. suction side pressure (cooling circuit)
1,0 MPa
Max. compression side pressure (cooling circuit)
2,3 MPa
Minimum space required for the operation (for installation without ventilation duct)
20 m
3
Operating temperature range
-7 – +38 °C
Max. water temperature
65 °C
COP 20 °C EN16174
3,36
COP 7 °C EN16174
2,92
Noise level
Outdoor Air duct.: 52 dB(A); Ambient 58 dB(A)
Type of outlet air
Air supply flowing vertically upward
Electrical heating
Heatable volume
80 l
Voltage/frequency
L/N/PE 230V~ / 50Hz
Fuse
5A / 250V~ (T)
Rated heating performance
1800W
Maximum current consumption
16 A
Heat-up time 10/55 °C
4,15 h
Maximum water temperature
65 °C
Minimum water temperature
10 °C
Miscellaneous
Heat insulation/thickness
Freon free PUR insulation / 50 mm
Tank
Enamelled steel sheet
Pipe coil
Enamelled steel pipe
Corrosion protection
active anode
Active anode maintenance
Anode consumption display
Built-in controller
Electric heating and temperature limiter device
Electrical connection
fixed
Protection grade
IPX1
Contact protection applied
Contact protection class I
The appliance can be connected to mains supply with protective earthing.
Regulations applicable to the product:
EN 60335-1 EN 60335-2-21 EN 14511-3 EN 16147
Storage and transport requirements
IEC 721-3-1 IE12 IEC 721-3-2 IE22
Certification of conformity
CE, TÜV CB, EHPA
Quality
Class I