Version V1.0 · 04/2022

Operation manual

Electronic solenoid valve control

IFC 24

Содержание IFC 24

Страница 1: ...Version V1 0 04 2022 Operation manual Electronic solenoid valve control IFC 24...

Страница 2: ...e Filteranlagen GmbH An der Imb ke 7 27798 Hude Germany Tel 49 4408 8077 0 Fax 49 4408 8077 100 Email info hainke de Internet www hainke de 2 Electronic solenoid valve control V1 0 04 2022 Operation m...

Страница 3: ...ne 22 5 2 Intended use 5 3 Technical data 6 4 Assembly and installation 8 4 1 Electrical connection 9 4 2 Dimension plan IFC 24 10 4 3 Connection plan IFC24 11 5 Start up 12 6 Control and message func...

Страница 4: ...35 EU 2014 34 EU Applied standards EN 55014 1 2012 EN 60204 1 2012 EN 60079 0 2014 EN 60079 31 2014 The named standards and directives can be examined at HAINKE Filteranlagen GmbH 1 2 Marking electri...

Страница 5: ...c tion IP54 must be maintained as a minimum 1 4 Notes on particular conditions for safe use in hazardous area Zone 22 Allowable ambient temperature range Ta 10 C to 40 C 1 Attach the control within th...

Страница 6: ...g diodes RED Lack of air wire break GREEN Status message active Message output Status message GREEN LED potential free make contact NO contact load max I 0 5 A U 230 VAC Control input F Remote control...

Страница 7: ...etic Compatibil ity EN 61000 6 1 EN 61000 6 2 EN 55014 1 Directive 2014 34 EU equipment and protective systems intended for use in potentially explosive atmospheres EN 60079 0 EN 60079 31 Equipment ma...

Страница 8: ...bration free location Mounting enclosure The control in the mounting enclosure is suitable for mounting in the installation The operation is permitted for Hazardous area Zone 22 non conductive dust th...

Страница 9: ...the terminal block Solenoid valves 1 The solenoid valves must be connected to terminals 1 10 of the terminal block 2 Route the positive terminal of the solenoid valves grouped together to terminals 25...

Страница 10: ...D C B A Datum Name Ma stab Blatt Elektronische Magnetventilsteuerung Typ IFC 24 E MASSPLAN 1 1 Masse ca A3 1 5 4 44 kg 255 235 200 128 250 6 x M 1 6 25 103 4 x M 2 0 4 x 5 4 Assembly and installation...

Страница 11: ...3 24 25 26 PE PE 12x1 00mm bei 7 10 Ventilen 14x1 00mm bei 11 12 Ventilen Die Adernummer kennzeichnet die Ventilnummer 25 30 Sammelleiter Pilotventilkasten bis 12 Ventile Pilotventilkasten bis 12 Vent...

Страница 12: ...DIP switch 1 ON Start the control via remote control or differen tial pressure switch DIP switch 1 OFF Direct start of the control on connecting the supply voltage DIP switch 2 ON Testing of the rate...

Страница 13: ...cleaning process starts immediately after the supply voltage is applied Input F must also be used to connect a differential pressure switch The differential pressure switch initiates the cleaning proc...

Страница 14: ...5 the control switches over to secondary cleaning after switching off via input F The started sequence is immediately run through with shortened pause time The actual secondary cleaning begins with t...

Страница 15: ...ssage Display Cause of error Remedy If the compressed air is not to be monitored set DIP switch 2 to the OFF position 7 Fault messages Operation manual Electronic solenoid valve control V1 0 04 2022 1...