4. Repeat 1-3 steps to set the 3-4 periods of Mon.
5. Press “Prog”, show “
” and “Tue”. Repeat 1-4 steps to set the 1-4 periods of Tue.
6. Repeat 1-5 steps to set Wed, Thu, Fri, Sat, Sun.
This thermostat has installed following initial values:
Week
Period 1
Period 2
Period 3
Period 4
Starting T / temp.
℃
Starting T / temp.
℃
Starting T / temp.
℃
Starting T / temp.
℃
Mon
7:00 20
℃
[68
℉
]
8:30 16
℃
[61
℉
]
17:00 22
℃
[72
℉
]
21:30 18
℃
[64
℉
]
Tue
7:00 20
℃
[68
℉
]
8:30 16
℃
[61
℉
]
17:00 22
℃
[72
℉
]
21:30 18
℃
[64
℉
]
Wed
7:00 20
℃
[68
℉
]
8:30 16
℃
[61
℉
]
17:00 22
℃
[72
℉
]
21:30 18
℃
[64
℉
]
Thu
7:00 20
℃
[68
℉
]
8:30 16
℃
[61
℉
]
17:00 22
℃
[72
℉
]
21:30 18
℃
[64
℉
]
Fri
7:00 20
℃
[68
℉
]
8:30 16
℃
[61
℉
]
17:00 22
℃
[72
℉
]
21:30 18
℃
[64
℉
]
Sat
7:30 21
℃
[70
℉
]
9:00 20
℃
[68
℉
]
17:30 22
℃
[72
℉
]
22:00 18
℃
[64
℉
]
Sun
7:30 21
℃
[70
℉
]
9:00 20
℃
[68
℉
]
17:30 22
℃
[72
℉
]
22:00 18
℃
[64
℉
]
PARAMETER SETTING LIST
Power off, press “mode” and “time” button at the same time and hold for 6 seconds, enter the parameter setting interface. Now press “clock” button to page down and “mode” button to
page up selecting parameter, and press “up” and “down” button to adjust the parameter value.
NO.
Parameter Setting Description
Default Value
Range
01 CC
Thermostat working time counter
0-1999 Days
02 Pr
4 periods mode choices:
52=5+2 4 periods;61=6+1 4 periods;74=7 4 periods;
no=have no 4 periods, it is manual or time on/off mode.
no
5+2 4 periods
6+1 4 periods
7days 4 periods
03 rH
Setting the highest room temperature range
35
℃
95
℉
10-45
℃
50-113
℉
04 rL
Setting the lowest room temperature range
5
℃
41
℉
3-9
℃
37-48
℉
05 FH
Setting the highest floor temperature range
45
℃
113
℉
20-60
℃
68-140
℉
06 FL
Setting the lowest floor temperature range
5
℃
41
℉
5-10
℃
41-50
℉
07 CF
Celsius /Fahrenheit, 24/12 hours :12
℃
,24
℃
,12
℉
,24
℉
24
℃
08 Fr
Low temperature protecting function on/off: 0=off;1=on
0
0-1
09 dB
Difference setting
2
℃
/
℉
1-9
℃
/
℉
10 5E
Sensor mode: 0=only inside; 1=only outside;2=both inside and outside.
0
0-2
11 rC
Room temperature adjustment
0
℃
/
℉
-9-9
℃
/
℉
12 FC
Floor temperature adjustment
0
℃
/
℉
-9-9
℃
/
℉
13 BC
Compensation factor adjustment
47
30-99
14 dd
Auto recovery: 0=auto recovery;1=no auto recovery;2=power on
0
0-2