background image

IMPORTANT INFORMATION

SAVE THESE INSTRUCTIONS

Installation Instructions

Tools Required: Phillips Screwdriver, Insulated Wire
Connectors (Wire Nuts®), Wire Strippers, Wire Cutters

TEL: 360-693-2505  Fax: 360-694-8668  P.O. Box 1675  Vancouver, WA  98668-1675

PLEASE READ THROUGH THESE INSTRUCTIONS BEFORE
PROCEEDING WITH INSTALLATION OF THE “SBFT2”
THERMOSTAT INTO A CADET SERIES “F” BASEBOARD

For All Applications

The thermostat needs to be mounted into the same junc-
tion box (wiring compartment) as the supplied electrical
power.  If the supplied case ground conductor is not in this
junction box it will need to be relocated to the end wired.

The installation of the SMART-BASE thermostat may
require a slight adjustment of the panel across the front of
the heater, to allow the thermostat to fit into the junction
box unobstructed.  To do so, remove both junction box cov-
ers and unlatch the bottom of the panel from its hangers.
(Use a rubber-coated tool, or hammer handle to remove
the panel. Carefully pry upward to remove.) Next, slide it
back out of the junction box opening to be used for the
thermostat until its edge is just hanging over the partition.
Hold the panel and snap it back on to its hangers.  The
thermostat will now have enough room to fit into the junc-
tion box opening.

Replacing Existing BTF Thermostat Control

SBFT2

SMART-BASE

Thermostat 

Installation Instructions

1. Remove screw attaching the existing BTF assembly

(thermostat and plate) to the baseboard case and care-
fully pull it back to expose the wiring and connections.
(Test with meter or circuit tester to verify that no electri-
cal power is present before proceeding.)

2. If the power supply has been brought into the base-

board at this junction box, undo the wiring connections
and remove the old thermostat assembly.  Follow the
appropriate wiring diagram (“FIGURE A” for left end

attachment, “FIGURE B” for right end attachment) and
the following instructions “Baseboard/Thermostat
Wiring” below to connect the SBFT2 to the baseboard
and power supply.

3. If the power supply has not been brought into the base-

board at this junction box, remove the old thermostat
assembly by removing the wiring connections.  The new
thermostat (SBFT2) must be located in the same junction
box as the supplied electrical power; therefore, strip 1/2"
of insulation from the two loose leads (created when the
thermostat was removed) and join the two wires back
together using a wire connector.  Remove the end plate
from the other junction box and apply it to the junction
box where the thermostat was removed.  Follow the
appropriate wiring diagram (“FIGURE A” for left end
attachment, “FIGURE B” for right end attachment) and
the following further instructions “Baseboard/Thermostat
Wiring” to connect the SBFT2 to the baseboard and
power supply.

As Part of New Installation

Install the Cadet “F” series baseboard heater according to
the installation instructions supplied with the product.  Keep
in mind the SBFT2 thermostat needs to be mounted into the
same junction box (wiring compartment) as the supplied
electrical power. If the supplied case ground conductor is
not in this junction box it will need to be relocated to the
end wired.

IMPORTANT!

It is extremely impor-

tant that you verify

the electrical power
to be supplied to the

heater is the same

voltage as the heater.

Connecting a heater

to a lesser voltage

supply than is intend-

ed will reduce the

heater's output, and

connecting it to a

greater voltage sup-

ply than it is intended

can cause property

damage and personal

injury.  The electron-

ic thermostat will
only function cor-

rectly on 240 & 208

volt circuits.

TM 

WARNING

Turn the electrical power off at the electrical panel
board (circuit breaker or fuse box) and lock or tag the
panel board door to prevent someone from turning on
power while you are working on the heater. Failure to
do so could result in serious electrical shock, burns,
or possible death.

©2005 Cadet Manufacturing Co.

Printed in U.S.A.   12/05 #720004

Содержание SBFT2 Smart-Base

Страница 1: ... end attachment and the following instructions Baseboard Thermostat Wiring below to connect the SBFT2 to the baseboard and power supply 3 If the power supply has not been brought into the base board at this junction box remove the old thermostat assembly by removing the wiring connections The new thermostat SBFT2 must be located in the same junction box as the supplied electrical power therefore s...

Страница 2: ...hammer handle carefully pry upwards 4 Carefully push wiring back into junction box hook upper edge of faceplate under lip of case Lower bottom edge of faceplate to junc tion box surface and secure thermostat with mounting screw 5 Rocker switch should be placed in the 0 OFF position To finish see the Completion of Installation section below FIGURE A Left Junction Box Wiring FIGURE B Right Junction ...

Страница 3: ...IGURA A para el accesorio del extremo izquierdo FIGURA B para el del extremo dere cho y las siguientes instrucciones para el Cableado del zócalo termostato a fin de conectar el SBFT2 al zócalo y la fuente de alimentación 3 Si la fuente de alimentación no se ha empalmado al zócalo en esta caja de empalmes quite el conjunto del termostato antiguo retirando las conexiones de cableado El nuevo ter mos...

Страница 4: ...dadosamente el cableado para volver a introducirlo en la caja de empalmes enganche el borde superior de la placa delantera bajo el reborde del chasis Baje el borde inferior de la placa delantera a la superficie de la caja de empalmes y fije el termostato con el tornillo de montaje 5 El interruptor basculante se debe poner en la posición de apagado 0 OFF Para terminar consulte la sección Completar ...

Страница 5: ...DULE program mode press the up button once The first display will be the WAKE time for Monday through Friday Time adjustments are made in 15 minute increments 4 To program the LEAVE time setting press the down button to decrease the time or the up button to increase When the time setting is correct press the MODE button to advance to program the RETURN time setting 6 To program the SLEEP time sett...

Страница 6: ...E pulse el botón ascendente una vez La primera pantalla corresponderá a la hora de despertar WAKE para los días hábiles Los ajustes de hora se realizan en incrementos de 15 minutos 4 Para programar el ajuste de la hora de salida LEAVE pulseelbotóndescenden te para bajar la hora o el botón ascen dente para subirla Cuando el ajuste de la hora sea el correcto pulse el botón Modo MODE para avanzar a l...

Отзывы: