15 rE 

When power re-supplied, relay time adjustable.   

Default =0, relay time is 10 seconds 

0 min 

0-15min 

16 DE 

Temperature-variation caused relay off-on process time set 

0 min 

0-15min 

17 O5 

Auto-adjustable function on and off 0=off, 1=on 

0-1 

18 OP 

Preheat output displayed in advance setting 

3h 

0-3h 

19 CO 

Set preheat output value 

20min 

10min 

10-120min 

5-60min 

20 Oh 

Set only outside sensor‘s highest temperature 

90

 

194

 

30-90

 

85-194

 

21 OL 

Set only outside sensor‘s lowest temperature 

0

 

32

 

0-10

 

32-50

 

NOTE: 

(*) Only Auto-adjustable function on, parameter shows No.18, No.19. 

(**) Only choose single outside sensor, parameter shows No. 20, No.21. 

 

FLOOR TEMPERATURE EXAMINATION AND SETTING 

 Check the floor temperature: power on status, press “Mode” one time, LCD shows “

”, “XX.X

” or “XX

” shows the floor temperature. Single sensor setting is without this function. 

  Set  the  floor  temperature:  power  off  status:  press  “Mode”  for  7  seconds,  until  LCD  shows  “SET  XX.X

”  or  “SET  XX

”,  then  press  “Up”  or  “Down”  to  set  the  floor  protection 

temperature. Default Setting is 35

℃ 

[95

]. 

LOW TEMPERATURE PROTECTION

 

 When the low temperature protection is valid, thermostat turns off and the room temperature (or floor temperature) is lower than 5

  [41

], the thermostat will auto start heating and 

show “ ”, turn on the electric heating equipment, when the room temperature (or floor temperature) increases to 7

  [45

], the thermostat will end output auto. 

 The on /off of the low temperature protection function, please refer to the “Parameter Setting Table”. 

WIRING DIAGRAM 

 

 

 

 

 

 

 

 

 