background image

 

switch the mode to manual “01” or 4 periods “03”. 

4 EVENTS PROGRAMMING SETTING 

  Dividing  a  week  into  seven  separate  days  or  5+2/6+1(Monday….Friday  +  Sat  Sun/  Mon….Sat  +  Sun),  each  day  has  four  periods  with  different  setting  temperature  to  meet  with 

customer’s individual demand.   

Temperature unit default is Fahrenheit, if need to change into Degrees Celsius, please refer to “parameter setting datasheet”. 

       

Taking Working days (Mon-Fri), Resting days (Sat-Sun) 4 periods setting as an example, reference as below:

 

 Working day setting : period 1 setting : press “Prog” ,and LCD shows “

” and “Mon Tue Wed Thu Fri”, “hh” flashes in “hh:mm”, and then press “Up” or “Down” to set hours; press 

“Prog”, “mm” flashes in “hh:mm”, and then press “Up” or “Down” to set minutes; press “Prog”, temperature flashes, and then press “Up” or “Down”    to set the temperature, and the other time 

period is set by the same way. 

 Resting day setting: Press “Prog” till to show “

” and “Sat Sun” and then set as the above method. 

Please separate each time period when set the above time period, so as to avoid the system work fault.

 

This thermostat has installed following initial values: 

5+2   

Working days/Resting 

days 

Period 1 

Period 2 

Period 3 

Period 4 

Starting T / temp.

 

Starting T / temp.

 

Starting T / temp.

 

Starting T / temp.

 

Working days

Mon-Fri

 

7:00      20

  [68

8:30    16

  [61

17:00    22

  [72

21:30    18

 [64

Resting days

Sat-Sun

 

7:30      21

  [70

9:00    20

  [68

17:30    22

  [72

22:00    18

 [64

 Cancelling Working days /Resting days 4 periods function, please as per the tip of the    “manual mode, timer on/off function mode and 4 periods mode choices” , switch the mode to 

manual ”01” or timer on/off “02”. 

Taking Working days, Resting day 4 periods setting as an example, this thermostat has installed following initial values:   

6+1 

Working days/Resting 

days 

Period 1 

Period 2 

Period 3 

Period 4 

Starting T / temp.

 

Starting T / temp.

 

Starting T / temp.

 

Starting T / temp.

 

Working days

Mon- Sat

 

7:00      20

 [68

8:30    16

  [61

17:00    22

  [72

21:30    18

  [64

Resting day

Sun

 

7:30      21

 [70

9:00    20

  [68

17:30    22

  [72

22:00    18

  [64

Take each day’s 4 periods of a week (7days) as an example, reference as below: 

7 days 4 periods programmable: Separate each day into 4 periods, each period includes the start time and the programmable temperature. 

Before follow below steps to program the 7days, please layout the starting time and temperature. 

Press “Prog”, LCD shows “

” and “Mon”, as per the initial value datasheet and follow steps to set the 4 periods program of Mon. “hh” flashes in “hh:mm”, press “Up”, “Down” to set the 

hour of the program. Press “Prog”, “mm” flashes in “hh:mm”, press “Up” or “Down” to set the minute of the program. Press “Prog”, program temperature flashes, press “Up”, “Down” to set the 

program temperature. 

1. Press “Prog”, “hh” flashes in “hh:mm”, press “Up”, “Down” to set the hour of the second period program.   

2. Press “Prog”, “mm” flashes in “hh:mm”, press “Up”, “Down” to set the minute of the second period program. 

3. Press “Prog”, program temperature flashes, press “Up” or “Down” to set the adjustable temperature.   