– 9 –
Circulation Pump
: 120 VAC, .8 amp – 3.8
LRA, 8GPM @ 5PSI
Drain Pump
second cycle
Tub TCO
: 120 VAC, 210°F +/- 10°F Manual
Reset
Main Control
: Input 120 VAC, Output 120
VAC, and Output 5 and 13.5 VDC
Heater 120 VAC
Wet
Dry
Watts
800
500
+/- 5%
Ohms
18
28.8
+/- 5%
Amps
6.67
4.17
+/- 5%
Resistance Temperature
20k
50°F
11k
75°F
5.8k
100°F
3.4k
125°F
2.1k
150°F
1.3k
175°F
Product
Product
Door Switch
: 13.5 VDC
Water Valve
minute cycle time
UI Control
: 13.5 VDC (some models have
13.5 VDC output to detergent module and dry
fan)
to release detergent cup, 15 seconds to
release rinse aid
Fan Assist Dry
GDP615HxM0xx only
, 13.5
VDC
Flood Switch
: 13.5 VDC, .42 amp
Turbidity Sensor
Models
GDF510PxM0xx, GDF511PxM0xx and GDT535PxM0xx have a tub thermistor.
Models GDF530PxM0xx, GDF630PxM0xx, GDF640HxM0xx, GDT605PxM0xx,
GDT635HxM0xx and GDP615HxM0xx the thermistor is located in the Turbidity Sensor
~ 70 pounds (depending model)
33 3/8"
34 5/8"
23 3/4"
24"
to neutral (see Drain Pump Diagnostic
section of this guide).