CONNECT SERIES SERVICE MANUAL
71
ENGLISH
Maintenance
Compressor Disassembly
Note: Be sure the refrigerant is recovered and power is isolated before removing the compressor.
Step
Picture
Work instruction
6. Connect the pipes to the
suction and discharge ports.
Braze the compressor connection pipes
and connect them to the compressor.
Note: When replacing the compressor,
avoid touching the nearby pipeline and
components.
7. Connect the compressor
Connect the compressor wires to
the wire terminals on the top of
compressor.
Note: When connecting the wires,
be sure to match the colors with the
corresponding wire terminals.