CONNECT SERIES SERVICE MANUAL
62
ENGLISH
Maintenance
Outdoor Coil Removal
Note: Make sure all refrigerant has been recovered and power is isolated before removing the outdoor coil.
Step
Picture
Work instruction
2. Remove the electric box.
Loosen the wire clamp at the
bottom of the electric box.
Unscrew the screws of electric box.
The connection wires inside and
outside the electric box should be
removed.
3. Remove motor support.
When removing the motor
support, be careful to protect the
components.
4. Remove the outdoor coil.
Heat the brazed joint with a torch
until the pipes separate.
Note: When brazing the pipes, do
not let the flame burn the other
components. The brazing points
of the outdoor coil are steel and
copper brazed points. Be sure to
maintain the brazing quality.
5. Remove the outdoor coil
Loosen the securing screws of coil
support. Take off the plate type
heat exchanger and the support as
a whole.