CONNECT SERIES SERVICE MANUAL
70
ENGLISH
Maintenance
Compressor Disassembly
Note: Be sure the refrigerant is recovered and power is isolated before removing the compressor.
Step
Picture
Work instruction
3. Break off the pipes that
connect to the compressor.
Braze the pipes that are connected to
the compressor.
Then remove the pipes.
Note: When brazing the pipes, do
not let the flame burn the other
components
4. Remove the compressor
from the chassis
Take out the compressor and replace it.
Note: When replacing the compressor,
avoid touching the nearby pipeline and
components.
5. Fix the new compressor
back onto the chassis.
After replacing the compressor,
tighten up the screws at the foot of
compressor.