Specification
8
Domestic air conditioner
exchanger Row*stage*fitch
1*12*1.32
TECHNICAL SPECIFICATIONS-OTHERS
Refrigerant
circuit
Refrigerant type
R32
Refrigerant charge
KG
0.
65
Maximum allowable distance
between indoor an outdoor
M
20
Maximum allowable level difference
●
m
1
0
Refrigerant control
EEV
Piping connections
(external diameter)
liquid
mm
Φ
6.35
gas
mm
Φ
9.52
drain
●
mm
Φ
16
Heat insulation type
Both liquid and Gas pipes
●
Max. piping Length
m
●
20
Max. Level Difference
m
1
0
Chargeless
m
Amount of Additional Charge of Refrigerant
g/m
20
Note: the data are based on the conditions shown in the table below
3.Sensors list
type
Description
Qty
Ambient sensor
Its used for detecting temperature of outdoor side
1
Defrosting sensor
Its used for controlling outdoor defrosting at heating mode
Descharging sensor Its used for compressor in case of over-heat
Conversation formulae
Kcal/h= kW×860
Btu/h= kW×341
3
cfm=m³/min×35.3
7
Piping length
heating
cooling
Indoor: 27
℃
DB/19
℃
WB
Outdoor: 35
℃
DB/24
℃
WB
Indoor:20
℃
DB
Outdoor: 7
℃
DB/6
℃
WB