Z-WAVE NODE ID
The Node ID is a unique number between 1 and 232 which identifies a Z-Wave device on the Vizia RF Z-Wave Network. Each
Node must be associated (mapped) with a unit number in the Omni IIe controller.
For Vizia RF Z-Wave pushbutton controllers, enter the Node ID for the Z-Wave pushbutton controller associated with that room
(e.g. Unit 1, Unit 9, Unit 17, etc). If desired, more than one pushbutton controller may be assigned to a room by associating the
pushbutton controller on any unit number in that room. If a second pushbutton controller is used, do not assign in a name in the
controller.
UNIT 1 NODE ID: 0
0-232
THROUGH
UNIT 64 NODE ID: 0
0-232
↑
Enter the Node ID (0-232) for each Z-Wave device followed by the ' # ' key.
Enter 0 if there is no node associated with the specified unit number.
SETUP ZONES
To configure wireless receivers, zone resistors and the zone types (definitions) for each security zone, from the Installer Setup
menu, select the 2 (ZONE) key.
Note:
There zone options that define the way that each zone functions. To access Zone Options, press the 8 (ZOPT) key.
WIRELESS RECEIVER
A Wireless Receiver can be used to add 16 zones (33-48) to the Omni IIe. If used, you must enable the following item:
WIRELESS RECEIVER: 0
0=NO 1=YES
↓
NOTES:
1.
Up to 2 Model 10A06 Hardwire Expanders can be used with the Omni IIe. Zones 1-16 on the first Expander are Zones 17-32
on Omni IIe. Zones 1-16 on the second Expander are Zones 33-48 on Omni IIe.
2.
When used, the Model 10A06 Hardwire Expander Modules must be configured under Setup | Installer | Expansion.
3.
If a Wireless Receiver is used, a second 10A06 Hardwire Expander cannot be used also. Transmitters 1-16 on the Wireless
Receiver are Zones 33-48 on Omni IIe.
ZONE RESISTORS
This item is used to specify if the 1000-ohm end-of-line zone resistors will be used with zone inputs other than Supervised Fire
and Gas. If this item is set to "Yes", all zones other than Supervised Fire and Gas will require an end-of-line resistor.
The default setting is "Yes".
ZONE RESISTORS: 1
0=NO 1=YES
Содержание OMNI IIe
Страница 2: ......
Страница 21: ...Page 15 BLACK RED RED FIGURE 8 SOUNDER CONNECTIONS...
Страница 73: ......
Страница 74: ...HAI New Orleans LA U S A...