3.2
C. AUXILIARY HYDRAULIC SYSTEM
Type ........................................................................................ Single closed center pump
Pump type ................................................................................ Load Sense
1
.
Booms
Type .........................................................................................Dry, with variable row spacing(optional wet)
Standard ...................................................................................60/80/90ft. (5 spray sections)
Controls ....................................................................................Electro-hydraulic: fold/lift/level
Level shock absorber ...............................................................Gas-charged accumulator
Outer boom tip hydraulic breakaway…………………………...Self-actuated, auto-reset hydraulic
2.Solution Fill Connection
Quick-fill connection .................................................................3 in. (7.6 cm) I.D.
3.Solution Tank
Standard ...................................................................................1400 gal. (5299.58
ℓ
) stainless steel w/sight
gauge
Agitation (stainless steel tank) .................................................Sparge-type w/elect. var. speed control
4.General Spray System
Pump ........................................................................................Centrifugal - hydraulically driven with
pulse width modulated control valve
Solution valves .........................................................................Electric ball valves
Pressure gauge ........................................................................100 PSI glycerin filled
Console ....................................................................................Raven 4600 (GPS-ready)
Fence row nozzle .....................................................................Two position, remote activated
D. SPRAY SYSTEM
E. FOAM MARKING SYSTEM
Make ........................................................................................ Hagie Foam Marker
Type ......................................................................................... Live air
F. RINSE SYSTEM
Spray system rinse (solution tanks, pump, and booms) .......... Standard
High pressure washing system ................................................ Optional
III.
SPECIFICATIONS
Содержание STS14
Страница 119: ...9 9 IX TROUBLE SHOOTING NOTES...