VII.
SERVICE AND MAINTENANCE
High Pressure In-line Filters
STACK VALVES -
The valves on the lift control stack
valve are protected by a 90 Micron in-line sintered bronze
filter (fig. 7.26). When the filter element is removed for
cleaning, caution should be taken so the gasket is in the
proper place when re-installing (fig. 7.27). Also, re-install
filter paying attention to direction of flow so the end
marked “OUT” is oriented correctly.
A/C System Dryer (if equipped)
The A/C system receiver/dryer (fig. 7.28) should be
replaced if the A/C loop is ever opened such as replacing
a compressor or condenser line, etc.
FILTERS CONTINUED
FILTERS CONTINUED
FIG 7.28
x
FIG 7.27
FIG 7.26