5. Electrical installation
a. Power supply
Power terminal block (230V/32A) for rigid cable of max. 10 mm².
Control terminal blocks of transmitter coils for rigid cable of max. 1.5 mm².
Power supply terminal block (230V) of the controller for rigid cable of max.
1.5 mm².
b. Maximum power load
The maximum power load is determined using the encoder wheel that can
be turned to the desired amperage.
If the LED indicator light is a solid red, turn off the power, wait for 15
seconds and then change the position of the encoder wheel to an
authorised threshold.
Then, turn on the terminal: a steady green light should light up.
-X1: 1/2
N
Three-phase power
supply 1
(-X1/-X2)
Controller power
supply
MZ203 Trigger circuit
connection
(-X3)
Three-phase power
supply 2
(-X3/-X4)
L1 L2 L3
N L1 L2 L3
N LST
N
N LST
L1
-X0:1
-X0
-X0:3
-X2: 3/4
MZ203 trigger circuit
connection
(-X1)
Wiring diagram (version-specific)
Maximum
charging
rate
3P station
1P station
6 A
Not authorised by ZE Ready
1.2
Not authorised by ZE Ready
1.2
10 A
13 A
16 A
20 A
25 A
32 A
40 A
Prohibited for the electrical safety of the terminals
50 A
63 A
y
o
PIN