Creation/modification of a whitelist from the 

badges

The terminal should be in the local access control 

mode (Access_control=1) with a blank USB key 

in the controller slot. Scan the desired badges 

individually (wait for the station to stop blinking 

before scanning the next badge) and scan the last 

one twice in a row. The badge numbers are saved 

and the "b1237 badges.txt" file is created on the 

key for verification.
To add cards, repeat the operation. The badges 

will be added and a new file will be created.

Turn the switch to "Lune".
Connect the 230Vac day/night signal to the PIN50&51 of the station.

Remark: in this case, any charging operation that has started will be completed, even if the 230Vac signal is no longer active.

d.  Deferred charging with 230Vac day/night signal

Electrical cabinet

Terminal 

block

C1 and C2

Terminal 

block

50 and 51

Station

Rigid cable 2 x 1.5 mm

2

Terminal is switched 

off

Controller 50 and 51 

Meter C1 and C2

C1

C2

Creation/modification of a whitelist or a super-user from the file

Retrieve the ‘b1237 badges.txt’ file by inserting a blank USB key, and rename it ‘b1237 whitelist.txt’. You can then directly add the corresponding badge 

numbers in the file in the correct order of the fields, without erasing the old numbers. The "b1237 whitelist.txt" file must contain all badge numbers. After 

modifying the file, insert the key with only the "b1237 whitelist.txt" file. 

Deleting the whitelist

Insert a USB key with only a "b1237 whitelist.txt" file without any badge numbers.

Remote access control via OCPP

In the case of a remote access control (Access_control=2), the fleet manager directly manages the authorisations from his server.
If there is no network:
• if the station is configured as restricted access (Network_failure=0) only a local whitelist can provide a charging authorisation; the whitelist will have to be 

created previously in the local access control mode (Access_control=1)
• if the station is configured as free access (Network_failure=1) the charging will be authorised upon presentation of a technically compatible RFID badge.

y

o

PIN

o

12

Содержание XEV6 Series

Страница 1: ...e installed only by a professional electrician fitter according to local applicable installation standards Conform to SELV installation rules 2 General description Strip light RFID Card Reader Socket...

Страница 2: ...rises the following parts Contact detection fixed on the contactor Controller MID energy meter version specific Grommet plate Controller power supply Terminal blocks 3 M3T2S socket lockable 1 M3T2S so...

Страница 3: ...6LE002957B 4 Attachment and connection a Diagrams for wall drilling without wiring space at the rear 713 765 1300 max 480 330 2 0 2 355 233 87 50 1395 max 235 4x not included 1 1 3...

Страница 4: ...6LE002957B b Diagrams for wall drilling with wiring space at the rear for XEV427 713 765 480 330 2 0 2 355 1300 max 233 87 50 1395 max 435 235 8 5 54 4x not included 2x 2x XEV427 4...

Страница 5: ...428 Terminal Installation Area 1472 1239 1089 2 0 2 1 7 5 355 175 110 325 650 325 70 350 250 190 250 500 250 Foundation C20 25 X0 Depth 80 cm Bedding Layer 5 cm C8 10 XEV426 In case of a chemical seal...

Страница 6: ...B The terminal MUST be mounted on its base BEFORE attaching the vector cabinet The equipotential bonding must be established between the terminal foot and base O 6 Earthing point to connect to the ear...

Страница 7: ...power wait for 15 seconds and then change the position of the encoder wheel to an authorised threshold Then turn on the terminal a steady green light should light up X1 1 2 N Three phase power supply...

Страница 8: ...pe A 40 A C curve 30 mA type A 40 A C curve 30 mA type B 40 A C curve 30 mA type B protections for the controller supply protections for the controller supply protections for the controller supply pro...

Страница 9: ...n TN or TT neutral point connection OK neutral point connection neutral point connection neutral point Max 50 Max 50 for the 5 stations Max 5 stations on 1 earthing connection Interconnection Electric...

Страница 10: ...Factory setting depending on the meter of sockets 3 and 4 Network_failure 0 1 0 Restricted access with recognised badges 1 Free access with compatible badges Access type in the absence of a network c...

Страница 11: ...http address of the OCPP server Depending on OCPP server configuration client Not active cpref N characters Terminal name seen from the OCPP server Default MAC address AttachedCable 0 1 Jumper cable A...

Страница 12: ...1 and C2 C1 C2 Creation modification of a whitelist or a super user from the file Retrieve the b1237 badges txt file by inserting a blank USB key and rename it b1237 whitelist txt You can then directl...

Страница 13: ...d management signal to the station s PINs 50 and 51 Edit the b1237 global cfg file as follows System y Pin 50 and 51 If 1 Partial charging override If 2 Full charging override Note in this case any ch...

Страница 14: ...lerance standard Flashing red 6x cycle Fault Defective communication between station and EV earthing fault earthing is cut but CP is looped via Neutral Flashing red 6x cycle Fault Defective communicat...

Страница 15: ...nication 3 Electric vehicle is overcharged The EV does not comply with the power limit set by the station 4 Ventilation required The vehicle requires additional ventilation the charging is blocked 5 F...

Страница 16: ...ation standards Conform to SELV installation rules Usable in all Europe M and in Switzerland Correct Disposal of this product Waste Electrical Electronic Equipment z Applicable in the European Union a...