6. Configuration of the terminal
a. Controller’s configuration file
Use the ‘b1237 global.cfg’ file to configure the controller.
Turn on the station, wait at least 1 minute before inserting the key, then wait 5 seconds before removing it. Rename the ‘b1237 diagnose.txt’ file to ‘b1237
global.cfg’ (Be careful with the extension!). You can now edit it using a basic text editor.
To apply a new configuration, edit the ‘b1237 global.cfg’ file and copy it to a blank USB key. Insérer la clé USB dans le contrôleur et attendre 5 secondes que
la LED à côté du slot ne clignote plus. Make sure to only save the settings you wish to edit in the new file along with the title of the section (see the example
below).
System
Computer
Modified file
b1237 global.cfg
Original file
b1237 diagnose.txt
y
o
PIN
10
b. Settings
Settings
Possible values
Explanations
Comments
And_Or
3
4
3 Dual M3
4 Dual M3+M2
Factory setting
Access_control
0
1
2
0 No access control
1 Local access control
2 Remote access control via OCPP server
Refer to the relevant chapter
Wh_per_impulse1
1
10
100
1 Wh/pulse
10 Wh/pule
100 Wh/pulse
Factory setting depending on the meter
of sockets 1 and 2
Wh_per_impulse2
1
10
100
1 Wh/pulse
10 Wh/pule
100 Wh/pulse
Factory setting depending on the meter
of sockets 3 and 4
Network_failure
0
1
0 Restricted access with recognised badges
1 Free access with compatible badges
Access type in the absence of a network connection
for a terminal managed by OCPP (Access control = 2)
Name
N caractères
Nom de la borne en local
MMI_type
1
1 Single LED
Factory setting
DN_mode
0
1
2
0 Start up via external 230 VAC signal
1 Partial load management
2 Total load management
See relevant chapter
DN_delay
Whole number between 0 and X
Time in minutes (< 1440 min) before authorising charge
after a night signal
Station_Address
Whole number between 1 and 30
Wittybus address
In the case of LLM
Main_colour
0
1
0 Green Default factory value
1 Purple Colour of the LED in place of green
Input_BP1
0
1
0 station push button
1 other
Input_BP2
0
1
0 station push button
1 other
Setpoint1
Whole number between 7 and 32
Amperes
Factory setting
Setpoint2
Whole number between 7 and 32
Amperes
Factory setting
LED_power
Whole number between 30 and 100 In % of maximum brightness
Code_wheel
0
1
0 code wheel used for each side
1 code wheel used for sum of the two sides
Phase_mode
0
L1
L2
L3
0 three-phase station or phase unknown
L1 single-phase station connected to phase 1
L2 single-phase station connected to phase 2
L3 single-phase station connected to phase 3
This field is only used if the single-phase station is
received on a three-phase TIC