10. Additional functions
Additional functions can be activated via the terminal strip of the FT 120.
.
10.1 Connection for
external LEDs
Terminal 1, 2:
A two-pin, bi-directional LED (red/green) can be connected. The LED shows the same status
as the LED of the external antenna and the FT 120 after a proper connection.
10.2 Inputs for external
switches
Terminal 6+7, 8+9:
Two signal inputs can be used as current-controlled inputs (optocoupler inputs). An internal power
source for controlling these inputs is available. They are controlled via potential free contacts.
The inputs can be queried via
→
macros
.
10.3 Potential free output
Terminal 10, 11, 12:
The FT 120 has a relay output (NO, NC and COM). This relay is controlled by
→
macros
.
10.4 5V output
Terminal 13:
The voltage at terminal 13 can be switched to the consumer to be switched for a direct control
of small consumers (such as piezo sound generators or other signal generators).
10.5 Macros
Macros are programmes that extend the functionality of the FT 120. They can control the relay (10,
11, 12) depending on input signals (6,7,8,9). Contact the manufacturer for the development of the
macros.
11. Troubleshooting
FT 120
Output
EFL
3
MLA
6
Power Output
Power
Supply
Output
MLA
8
Antenna/LED
1
2
3
4
5
6
7
8
9
10
11
12
13
1
2
3
4
5
6
7
8
9
10
11
12
13
External LED +
External LED -
Operating Mode
Operating Mode
Signal Ground
Signal Input 2
Signal Input 2
Signal Input 1
Signal Input 1
Relay NO
Relay NC
Relay COM
Output 5 V, max. 50 mA
For step-by-step instructions „
Installing macro
“ see illustrations starting on
page
55
.
MACRO
If an attempt is made to open a door with a user key
Acoustic signal is heard twice
User key is not authorised.
LEDs do not change from red to
green
Hold user key closer to antenna.
or
User key is not authorised.
The system does not open.
User key is not authorised.
or
The locking mechanism must be checked.
or
Plug-in connections must be checked.
Keys are lost
Perform a complete reset, re-teach programming and clearing key,
re-teach user keys (see Chapter
„
7.2 Procedure to follow if a user key is lost
“)
BA_DFT.book Seite 16 Dienstag, 24. Januar 2012 10:37 10