![Haehne DCX Скачать руководство пользователя страница 41](http://html2.mh-extra.com/html/haehne/dcx/dcx_quick-start-manual_3062370041.webp)
HAEHNE
Elektronische Messgeräte GmbH · Heinrich-Hertz-Str. 29 · D-40699 Erkrath Germany · Telefon 0211/9 25 91-0 · Fax 0211/9 25 91-20
http://www.haehne.de
Email: [email protected]
Parameter Table 41
Math functions (Block 6) / 61…68
Mathematical channel x
4 6
x
01
Function selection: OFF; 1: sum
function (parameter value 2 to 8
see Reference Manual)
0
0
8
4 6
x
11
Source 1 (01 - 58)
51
01
58
4 6
x
21
Source 2 (01 - 58)
52
01
58
4 6
x
31
Source 3 (OFF, 01 - 58)
0
0
58
only sum
3 6
x
11 Source 1 scaling at
zero signal (0 %)
0.0
-200.0
200.0
%
3 6
x
12 Source 1 scaling at
nominal signal (100 %)
50.0
-200.0
200.0
%
3 6
x
21 Source 2 scaling at
zero signal (0 %)
0.0
-200.0
200.0
%
3 6
x
22 Source 2 scaling at
nominal signal (100 %)
50.0
-200.0
200.0
%
3 6
x
31 Source 3 scaling at
zero signal (0 %)
0.0
-200.0
200.0
%
only sum
3 6
x
32 Source 3 scaling at
nominal signal (100 %)
33,4
-200.0
200.0
%
only sum
Analog outputs (Block 9) / 91…98
Analog output x
4 9
x
01
Source (OFF; 01-88)
5x
0
88
3 9
x
11
Filter adjustment
1
1
9999
ms
1=off
3 9
x
12
Factor
1.000
0.000
2.000
3 9
x
13
Upper voltage limitation
10.00
0.00
12.00
V
3 9
x
14
Lower voltage limitation
-10.00
-12.00
0.00
V
Amplifier (Block 5) / 51…58
Amplifier x
4
5 x
00
OFF; ON (average); ON (sum)
1
0
2
4
5 x
01
1. Source (41-48)
4x
41
48
DMS-inputs only
4
5 x
02
2. Source (OFF; 41-48)
0
0;41
48
DMS-inputs only
4
5 x
03
3. Source (OFF; 41-48)
0
0;41
48
DMS-inputs only
4
5 x
04
4. Source (OFF; 41-48)
0
0;41
48
DMS-inputs only
3
5 x
11
Value of zero adjustment
0.0
-100.0
100.0
%
3
5 x
12
Manual zero adjustment
(auto. entry)
auto
-200.0
200.0
%
100.0 % = 20 mV
rounded
3
5 x
21 Setting for defined load
100.0
10.0
110.0
%
3
5 x
22 Manual
amplifier adjustment
666.7
100.0
30000.0