![Haehne DCX Скачать руководство пользователя страница 16](http://html2.mh-extra.com/html/haehne/dcx/dcx_quick-start-manual_3062370016.webp)
HAEHNE
Elektronische Messgeräte GmbH · Heinrich-Hertz-Str. 29 · D-40699 Erkrath Germany · Telefon 0211/9 25 91-0 · Fax 0211/9 25 91-20
http://www.haehne.de
Email: [email protected]
HAEHNE
Elektronische Messgeräte GmbH · Heinrich-Hertz-Str. 29 · D-40699 Erkrath Germany · Telefon 0211/9 25 91-0 · Fax 0211/9 25 91-20
http://www.haehne.de
Email: [email protected]
DCX
16 Operation
4.2.4. Adjustment Mode
With the gain setting of the first amplifier channel to 1000, the procedure is illustrated by an example:
1. Level Selection
2. Password Input
Additional protection regarding faulty input. In level 1 to 7 the password corresponds to the level.
The field will be selected by simply pressing the
respective field.
By pressing the fields "^" or "v" the respective
digit increases or decreases.
With "OK" the password is confirmed.
y x
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
y x
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
Esc
˄
v
OK
Level 3
Password
0 0 0 3
By pressing the "Menu" field in the start screen, select the parameter to be adjusted by selecting the level,
block, channel and the parameter number.
The procedure is similar for all parameters. The parameters are explained in more detail in chapter 6
"Description of Parameters".
Currently, the following levels are assigned:
Level 1: - A display setting such as 2, 4, 6 or 8 display
- Configuration of the Anybus digital outputs
- Relay settings
Level 3 Continuous parameter values such as
Scaling, filtering and amplification
Level 4 Basic settings and combinations of the blocks
Level 7 basic settings of the Anybus, such as the
Slave address
Level 8
HAEHNE
basic settings for the hardware
(Only set by
HAEHNE
)