DCX
36 Block 9
Block
Channel 1...8
Number
Level
Configuration of
8 voltage outputs
6.3.8. Analog Outputs (Block 9)
The parameters of chapter 6.3.6. Controller (Block 7) and 6.3.7. Summer (Block 8) are
described in the Reference Manual.
Range:
0; 01…88
Standard: 5x (x: as channel)
0:
Analog output x OFF
At the Analog output x 0 V resp. 4 mA are always present
1. Digit: block
2. Digit: channel
Tabular overview of signal sources in chapter 8
Signal source for analog output x
4 9 x 0 I
Signal source
selection
Range:
1…9999
Designation in ms
Standard: 1 (Filter function not in operation)
Value of the moving average in msec.
From the value 52 onwards an additional peak suppression
function is activated. However, local peaks do not enter into the
average calculation. Example: High value for displays, lower value
for PLC inputs.
3 9 x I I
Filter time
(Block 9)
Analog output [1...8]
2 x 4 Channel
D/A-Converter
16-bit
01...88
49x01
39x13
Upper
voltage limit
39x11
Filter
time
39x14
Lower
voltage limit
Selection number: 9x
39x12
Factor