OPERATION
Edition:
09/2004
Page
D-13
Replaces:
Hot Press type PM-1056/160
Section. D.5.4
M
OBILE OPERATION USE
Check the working procedures for the belt/strap, checking guidelines 3210, 3220, 3225 or the
individual technical sheet for the product.
Free the two fastening rods (4), turn them downwards and raise the upper part of the press
(1). When opening out the rods make sure you do not bring them down heavily on the floor or
supporting surface
Position the belt as required on the steel heat stabilizer (8) and fasten it, making sure it is flat.
Position the upper part of the press (1) onto the lower part of the press (6) with the belt
fastened to the heat stabilizer (8) and any inserts.
Turn the two fastening rods upwards (4) and evenly lock them at the two ends of the press
Ensure there is no liquid in the cooling circuit. This happens when the normal joining cycle is
stopped (either deliberately or due to a black-out for example) during the cooling stage.
In this case it is necessary to act as follows
:
Disconnect all electrical supply
Disconnect the pipes bring water into the press
Empty the press circuit using jets of compressed air.
When blowing air to expel water from the circuit, make sure the water does not come into
contact with electrical equipment.
Use the portable compressor to bring the pressure cushion to compress the belt at the
desired pressure.
Using the regulating equipment PMR-XX (see its own manual) preselect the press's upper
and lower temperatures
Use the regulating equipment PMR-XX (see its own manual) to select the joining cycle seal
times.
Using the regulating equipment PMR-XX (see its own manual) start up the joining cycle.
At the end of the joining cycle (see control equipment manual), it is necessary to manual
manage the cooling of the press.
For this purpose the flexible water hose for the mobile refrigerator has to be connected to the
connectors on the (5) hot press and the electric pump started up (see 1.3.1 Necessary
accessories for mobile use).
Wait for the end of the set cooling cycle
Empty the air out of the presser cushions
Open the hot press and carefully take the belt out and allow it to cool at room temperature.
ATTENTION
When you take the belt out, the press’s parts are hot. Use suitable protective GLOVES.
Remove water from the cooling circuit with jets of compressed air, ensuring it is
completely emptied.