1
1. Technical
data
HSP 7 450.08
Heat output range
2,4-8,1 kW
Nominal heat output
8 kW
Height
1051 mm
Width
490 mm
Depth:
489 mm
Weight
121 kg
Diameter flue gas nozzle:
80 mm
Flue gas temperature at nozzle
196°C
Test feed pressure at nominal performance
:
12 Pa
Test feed pressure at partial performance
:
6 Pa
Flue gas mass flow rate in g/s at nominal heating performance
5.5 g/s
CO
-
content at 13%O2 flue gas (nom
. heat. perf./part.perf)
0.012/ 0.027%
Efficiency level (nom. heat. perf/part.perf)
90/94 %
CO-content resp. 13%O2 in the flue gas (nom.heat.perf/part.perf):
150/338 mg/Nm3
NOx- content at 13%O2 in the flue gas (nom.heat.perf/part.perf:
130/117mg/Nm3
OGC-content at 13% O2 in the flue gas:
< 5mg/Nm3
Dust content in the flue gas
:
17 mg/Nm3
Content of the reservoir (pellet tank
):
Approx. 12 kg
Combustion period with one tank fill (min./ max.):
Approx. 7 h/22 h
Approved fuel: low-dust wood pellets according to Ö-norm M 7135, DIN plus, EN
plus-A1
Diameter: 6 mm
Length: max. 30 mm
Space heating capacity according to Ö-Norm M 7521
:
max. 230 m3
Space heating capacity according to DIN 18893, continuous heating
:
250m3/145m3/98m3
Space heating capacity according to DIN 18893, timed heating
:
165m3/95m3/65m3
Power supply:
230V (50 Hz)
Electric power input (max.)
85 W
At normal operation:
Electrical ignition (for max. 15 minutes at start):
660 W
Safety mechanism of the electronic system: (F3)
T 0,315A, 250V
Safety mechanism of the ignition, of the auger, induced draught (F1,) (F2
reserve)
T 3,15A, 250V
T
ech
n
ic
al
d
at
a
Safety distances
Minimal distances from flammable materials:
side:
10 cm
rear:
10 cm
front (radiation area):
80 cm
Содержание 0545008000000
Страница 4: ......
Страница 6: ...2 2 Dimensional drawing Dimensional drawing 1051 494 490 63 230 15 489 57 80 ...
Страница 15: ...11 Maintenance works ...
Страница 16: ...12 5 Spare parts overview 5 1 Complete list HSP 7 450 08 Spare parts overview ...