10
4.3.3. Cleaning of the induced draught casing
NOTE
The induced draught casing can also be cleaned after removing the smoke pipes from the back side of the
stove
.
In case of deposits / grinding noises in the induced draught casing, please proceed as follows
:
• This casing becomes accessible for cleaning by opening the 4 screws shown in Figure 9 (see arrows).
• Remove the induced draught fan motor by pulling it off
.
• Clean the flue gas passes, the draught ventilator, and the flue gas pipes with a sweeping brush and an
ash vacuum cleaner
.
• Then reassemble the components in reverse order.
NOTE
Make sure that the seal is replaced in the correct place. It is imperative that defective seals be replaced.
NOTE
• Be careful with the electrical connections at the fan motor and their correct positions
.
Figure 18: Induced draught fan
1 Screws
2 Fan motor
3 Seal
4.3.4. Cleaning of the flue tubes - yearly