6-3
5.
Remove the fan cage. Open the locking levers at the two ends of the fan cage, and then lift the
fan cage out of the chassis.
6.
Disconnect the diagnostic panel cable from the system board.
7.
Remove the diagnostic panel:
a.
Press the release button on the diagnostic panel. The ejector lever pops out.
b.
Hold the ejector lever to pull the diagnostic panel out of the slot.
8.
Install a new diagnostic panel. For more information, see "
Installing the diagnostic panel
."
9.
Install the fan cage. Place the fan cage in the chassis and then close the locking levers at the
two ends of the fan cage.
10.
Install the access panel. Place the access panel on top of the server chassis and slide the
access panel toward the server front until it snaps into place.
11.
Install the removed security bezel. For more information, see "
12.
Rack-mount the server. For more information, see "
13.
Connect the power cord. For more information, see "
14.
Power on the server. For more information, see "
Installing front drive cages
Prerequisites
Use
to determine the location of the front drive cage you are installing depending on the
type of the drive cage. For information about the installation locations of the front drive cages, see
"Front panel view."
Table 6-1 Drive cage installation locations
Drive cage model
Installation locations
HDDCage-8UniBay
Drive cage bay 3 for the 8SFF UniBay server
Cage-8SFF-BAY1
•
Drive cage bay 1 for the 8SFF UniBay server
•
Drive cage bay 1 for the 8SFF SAS/SATA server
Cage-8SFF-BAY3
Drive cage bay 3 for the 8SFF SAS/SATA server
Procedure
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the security bezel, if any. For more information, see "
4.
Remove the access panel. Pressing the two unlock buttons on the access panel, slide the panel
toward the server rear, and then lift the panel to remove it.
5.
Remove the fan cage. Open the locking levers at the two ends of the fan cage, and then lift the
fan cage out of the chassis.
6.
Remove the processor mezzanine board. For more information, see "
7.
Install a front drive cage:
a.
Remove the blank (if any) from the slot for the diagnostic panel slot. Remove the screw that
secures the blank and then push the blank from the inside of the chassis to remove it.