6-2
Installing the diagnostic panel
WARNING!
To avoid bodily injury from hot surfaces, allow the server and its internal modules to cool before
touching them.
To install the diagnostic panel:
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the security bezel, if any. For more information, see "
4.
Remove the access panel. Pressing the two unlock buttons on the access panel, slide the panel
toward the server rear, and then lift the panel to remove it.
5.
Remove the fan cage. Open the locking levers at the two ends of the fan cage, and then lift the
fan cage out of the chassis.
6.
To install the diagnostic panel for the first time, remove the blank and install the 1SFF cage:
a.
Remove the blank from the slot in which the diagnostic panel will be installed. Remove the
screw that secures the blank and then push the blank from the inside of the chassis to
remove it.
b.
Insert the 1SFF cage provided with the diagnostic panel into the slot and secure the 1SFF
cage with the fastening screw.
7.
Install the diagnostic panel:
a.
Connect the diagnostic panel cable to the diagnostic panel.
b.
Push the diagnostic panel into the slot until it snaps into place.
c.
Connect the other end of the diagnostic panel cable to the diagnostic panel connector on
the system board. For more information about the location of the diagnostic panel connector,
see "System board components."
8.
Install the fan cage. Place the fan cage in the chassis and then close the locking levers at the
two ends of the fan cage.
9.
Install the access panel. Place the access panel on top of the server chassis and slide the
access panel toward the server front until it snaps into place.
10.
Install the removed security bezel. For more information, see "
."
11.
Rack-mount the server. For more information, see "
12.
Connect the power cord. For more information, see "
13.
Power on the server. For more information, see "
Replacing the diagnostic panel
WARNING!
To avoid bodily injury from hot surfaces, allow the server and its internal modules to cool before
touching them.
To replace the diagnostic panel:
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the security bezel, if any. For more information, see "
4.
Remove the access panel. Pressing the two unlock buttons on the access panel, slide the panel
toward the server rear, and then lift the panel to remove it.