6-19
3.
Connect cables for the standard PCIe Ethernet adapter.
4.
Install the access panel. Place the access panel on top of the server chassis and slide the
access panel toward the server front until it snaps into place.
5.
Rack-mount the server. For more information, see "
6.
Connect the power cord. For more information, see "
7.
Power on the server. For more information, see "
Replacing a drive backplane
WARNING!
To avoid bodily injury from hot surfaces, allow the server and its internal modules to cool before
touching them.
Removing a drive backplane
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the drives attached to the backplane.
4.
Remove the access panel. Pressing the two unlock buttons on the access panel, slide the panel
toward the server rear, and then lift the panel to remove it.
5.
Remove the fan cage. Open the locking levers at the two ends of the fan cage, and then lift the
fan cage out of the chassis.
6.
Disconnect cables from the backplane.
7.
Remove the drive backplane. Loosen the captive screws that secure the backplane, and then
lift the backplane out of the chassis.
Installing a drive backplane
1.
Install a drive backplane. Place the backplane in the slot and then fasten the captive screws.
2.
Connect cables to the drive backplane.
3.
Install the removed fan cage. Place the fan cage in the chassis and then close the locking levers
at the two ends of the fan cage.
4.
Install the access panel. Place the access panel on top of the server chassis and slide the
access panel toward the server front until it snaps into place.
5.
Installed the removed drives.
6.
Rack-mount the server. For more information, see "
7.
Connect the power cord. For more information, see "
8.
Power on the server. For more information, see "
Replacing the processor mezzanine board
Removing the processor mezzanine board
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."