The storage controller allows you to hot swap drives. You can remove or replace failed drives
without shutting down the server system or powering off the server. This feature improves disaster
recovery capability and capacity scalability of the server.
Applicable scenarios
You can use this feature to replace drives without powering off the server.
RAID creation with NVMe drives
About RAID creation with NVMe drives
You can use Intel VROC or specific storage controllers to create RAIDs with NVMe drives to meet
performance, cost efficiency, and high availability requirements.
Applicable scenarios
This feature is applicable to scenarios where you need to create RAIDs with NVMe drives.
IO Bypass
About IO Bypass
IO Bypass can provide an optimized data path for drives. With IO Bypass enabled, the driver can
bypass the hardware RAID stack through the optimized path, and directly read and write
information from drives. This improves the waiting time for accessing information from the drive.
To use this feature, install a storage controller that supports IO Bypass, and make sure the
operating system driver support IO Bypass as well.
Applicable scenarios
This feature is applicable to scenarios where businesses have low requirements for read/write
latency of SSD logical disks, and require IOPS greater than 300K.
Содержание UniServer R4300 G6
Страница 36: ...21 Figure 23 Selecting the controller and RAID level 4 Select drives and then click Next...
Страница 40: ...25 Figure 27 Selecting the RAID array to be deleted 2 In the dialog box that opens click Yes...
Страница 41: ...26 Figure 28 Confirming the deletion 3 Verify that the RAID array has been deleted on the Volumes page...
Страница 65: ...23 Figure 36 Modifying RAID parameters 6 Confirm the RAID volume information and then click Create Volume...
Страница 66: ...24 Figure 37 Confirming RAID creation 7 Click OK to complete the RAID creation...
Страница 70: ...28 Figure 41 Setting the selected drive as a hot spare drive 4 In the dialog box that opens click Yes...
Страница 73: ...31 Figure 44 Deleting a RAID array 3 In the dialog box that opens click Yes as shown in Figure 45...
Страница 164: ...89 Figure 158 Selecting Main Menu 2 Select Controller Management and press Enter...
Страница 301: ...70 Figure 116 Array Configuration screen 3 On the screen as shown in Figure 117 select the target array and press Enter...
Страница 312: ...81 Figure 129 Erasing a drive 3 On the screen as shown in Figure 130 select the erase pattern and press Enter...
Страница 321: ...90 Figure 138 Configure Controller Settings screen for the RAID P460 B2...
Страница 330: ...99 Figure 147 Manage Arrays screen 5 On the screen as shown in Figure 148 select Create Logical Drive...
Страница 469: ...19 Examples Viewing physical drive informatoin Syntax mnv_cli info o pd Examples...
Страница 512: ...6 2 Select Main Menu and then press Enter Figure 9 Selecting Main Menu 3 Select Drive Management and then press Enter...
Страница 513: ...7 Figure 10 Selecting Drive Management 4 Select the target drive and then press Enter...
Страница 514: ...8 Figure 11 Select the target drive 5 View the value of the Status field...
Страница 521: ...15 Figure 22 Selecting the storage controller 2 Select Main Menu and then press Enter Figure 23 Selecting Main Menu...
Страница 529: ...23 Figure 33 Identifying a storage controller 2...