background image

 

3-3 

(1)  Remove the ICM. Press the unlock button on the ICM to fully open the ejector, and slowly pull 

the ICM out of the chassis horizontally. 

(2)  Put the ICM into the ESD bag. 

(3)  Install the ICM. Take out the ICM to be installed from the ESD bag. 

(4)  Press the unlock button to automatically open the ejector. 

(5)  Slowly insert the ICM into the chassis horizontally with UP facing upwards, and then lock the 

ejector. 

Содержание UniServer BT716F

Страница 1: ...H3C UniServer BT716F Straight Through Module User Guide New H3C Technologies Co Ltd http www h3c com Document version 6W100 20230224...

Страница 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Страница 3: ...red syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices separated by vertical bars from which you select one or none x y As...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...onnection 2 7 2 5 1 Connections Between Straight Through Modules and Mezz NICs 2 7 2 5 2 Internal Connections Between Straight Through Modules and Blade Server Mezz NICs 2 9 2 5 3 Internal Connection...

Страница 7: ...g Port Status of Straight Through Module Through OM Modules 5 1 5 1 2 Viewing through the OM CLI 5 2 6 Configuring the Straight Through Module 6 1 6 1 Changing the Port Rate 6 1 6 2 Common Operations...

Страница 8: ...Do not work alone when performing live line maintenance Do not touch the power supply directly or indirectly through conductive objects to prevent electric shock 1 2 Safety Precautions When maintainin...

Страница 9: ...Discharge When removing or installing the device you can use one or multiple of the following grounding methods to prevent electrostatic discharge Wear an ESD wrist strap and ensure that it is reliabl...

Страница 10: ...straight through module for the H3C UniServer B16000 blade enclosure It provides an external data interface which enables direct connection of parallel cables to the FC Mezz NIC port of the blade ser...

Страница 11: ...interfaces of the straight through module as well as the correspondence between interface and blade server slot 2 3 1 Interface Numbering Rules The numbering rule of FC interfaces of the straight thr...

Страница 12: ...2 3 Figure 2 2 Interfaces 2 3 2 Description of Interfaces Figure 2 3 shows the external interfaces on the panel of a straight through module Table 2 2 lists details about the interfaces...

Страница 13: ...e Name Type Quan tity Interfaces Description 1 AMC serial port RJ 45 1 This serial port is used to access the AMC CLI It is only used by technical support engineers to display the status of the 32G FC...

Страница 14: ...an be changed with the OM module For details see 6 1 Changing the Port Rate Straight through module interfaces are in direct correspondence to the blade server For details see 2 5 3 Internal Connectio...

Страница 15: ...UID UID Steady on blue The UID indicator is activated through the OM module UID 2 RUN RUN Steady on green off The system is faulty Blinking green at a frequency of 4 Hz The system is loading data Blin...

Страница 16: ...For details see 2 5 2 Before accessing the blade server through the straight through module you need to know how the connection between the interface of the straight through module and the target bla...

Страница 17: ...the internal connection between the straight through module and the Mezz NIC of the blade server Where The onboard NIC is connected to the active and standby OM modules Mezz NIC 1 and Mezz NIC 4 are c...

Страница 18: ...you need to specify the connection between the Mezz NIC port and the straight through module For details contact Technical Support 2 5 3 Internal Connection Between the Direct Module Interface and th...

Страница 19: ...ce between external interfaces of straight through module and full width single height blade server supports up to 3 Mezz NICs When both full width single height blade servers and half width single he...

Страница 20: ...s For details about blade server Mezz NIC ports that are connected to straight through modules contact Technical Support Figure 2 8 Internal connections between external interfaces of straight through...

Страница 21: ...port 1 and port 2 are connected to blade server 1 and users can access blade server 1 through port 1 or port 2 Port 3 and port 4 are connected to blade server 3 and users can access blade server 3 thr...

Страница 22: ...upports up to 3 Mezz NICs is installed in the front slots of the chassis As shown in Figure 2 11 the straight through modules connected to slots 1 3 4 and 6 are connected to blade servers through odd...

Страница 23: ...odules connected to slots 2 and 5 are connected to blade servers through even number interfaces That is port 2 is connected to blade server 1 and users can access blade server 1 through port 2 port 4...

Страница 24: ...hrough module the AMC unit is mainly responsible for board data collection and reporting board power on off control and system monitoring PHY unit As the data transmission unit of the straight through...

Страница 25: ...chassis and the installation slots are ICM 1 to ICM 6 at the rear of the chassis The straight through module is hot swappable The installation positions of the straight through modules and Mezz NICs m...

Страница 26: ...2 17 Figure 2 14 Straight through module installation guidelines 1 ICM1 slot 2 ICM2 slot 3 ICM3 slot 4 ICM4 slot 5 ICM5 slot 6 ICM6 slot...

Страница 27: ...tion NIC FC730i Mb 2P 2 2 port 32G FC Mezz Card 730i 2 8 2 Optical Modules Table 2 7 describes the optical modules supported by the straight through module Table 2 7 List of optical modules cables sup...

Страница 28: ...rent transmission of data between the blade server and the external network Blade servers configured with different types of Mezz NICs can be connected to different external networks through the exter...

Страница 29: ...n Tools The following tools or devices may be required when you install use and maintain the equipment Table 3 1 Required tools Table 3 2 Tool requirements Image Name Description Diagonal pliers Used...

Страница 30: ...ing Properly wear and ground the ESD wrist strap Remove conductive objects such as jewelry or watch The ICM is hot swappable Before replacing a component check the slots and connectors and ensure that...

Страница 31: ...e ICM out of the chassis horizontally 2 Put the ICM into the ESD bag 3 Install the ICM Take out the ICM to be installed from the ESD bag 4 Press the unlock button to automatically open the ejector 5 S...

Страница 32: ...h module that has already been installed before chassis power on will be automatically powered on when the chassis is powered on Manual operation is not required The straight through module that is in...

Страница 33: ...CLI 1 Viewing through the OM web UI 2 Prerequisites Before viewing the port connection status of the straight through module through the OM web UI complete the following operations Power on the strai...

Страница 34: ...ugh module The viewing of port status of straight through module in ICM slot 1 is taken as an example here OM display io port io 2 Internal connectors Interface Status Input speed kbps Output speed kb...

Страница 35: ...ate change 3 Notes The external port rate of straight through module needs to be selected based on the optical module rate Otherwise the status of the external port of straight through module cannot b...

Страница 36: ...through the LAN Ensure that the IP addresses of the PC and OM module are accessible on L3 Figure 6 1 Setting up the hardware environment As shown in of Figure 6 2 2 open the browser on the PC and ente...

Страница 37: ...ssis 1 Obtain the login data of the OM module The default data for logging in to the OM module CLI is shown in Table 6 2 2 Procedures 1 Connect the Ethernet port of the PC to the MGMT port of the prim...

Страница 38: ...ement IP address default 192 168 100 100 Subnet mask default 255 255 255 0 User name and password used to log in to the OM module User name default admin Password default Password _ By default the SSH...

Страница 39: ...7 1 7 Firmware Upgrade For specific procedures see H3C UniServer B16000 Upgrade Guide...

Страница 40: ...i Contents Appendix A Technical support 1 Collecting fault information 1 Preparing the maintenance tools 1 Appendix B Product recycling 2 Appendix C Glossary 3 Appendix D Acronyms 4...

Страница 41: ...the straight through module Product serial number Product model and name Snapshots of error messages and descriptions Straight through module insertion replacement and removal history in the chassis P...

Страница 42: ...o ensure that hardware at the end of its life is recycled Vendors with product recycling qualification are contracted to New H3C to process the recycled hardware in an environmentally responsible way...

Страница 43: ...able module can be installed or removed while the server is running without affecting the system operation R Redundancy A mechanism that ensures high availability and business continuity by providing...

Страница 44: ...C CLI Command Line Interface F FC Fiber Channel FCoE Fibre Channel over Ethernet FCF FCoE Forwarder I ICM Interconnect module IRF Intelligent Resilient Framework M Mezz Mezzanine N NPV N_Port Virtuali...