2-2
Category
Item
Description
Maximum
weight
3.35 kg
Power
consumption
Maximum
power
consumption
25 W
Environment
specifications
Temperature
•
Operating temperature: 5°C to 45°C
•
Storage temperature: -40°C to 70°C
Humidity
•
Operating humidity: 8% to 90% (non-condensing)
•
Storage humidity: 5% to 95% (non-condensing)
Altitude
•
Operating altitude: -60 m to +5000 m (The allowed maximum
temperature decreases by 0.33 °C as the altitude increases by 100 m
from 900 m)
•
Storage altitude: –60 m to +5000 m
2.3 Interface
This section describes numbering rules, positions, quantity, and other information about the
interfaces of the straight-through module, as well as the correspondence between interface and
blade server slot.
2.3.1 Interface Numbering Rules
The numbering rule of FC interfaces of the straight-through module is defined by "A/B/C".
•
A: Defaults to 1; cannot be edited.
•
B: Distinguishes between internal and external Ethernet interfaces. 0 indicates an internal
interface, and 1 indicates an external interface. Since a straight-through module does not
have any internal interfaces, this part in the number is 1.
•
C: Indicates the sequence number of the interface on the straight-through module; consistent
with the interface silk screen number on the panel.
For example, for an interface with a silk screen number "6" on the panel of the straight-through
module, the interface number is "1/1/6".