Configuring the system to identify the new storage controller
After a replacement, storage controller consistency check might fail if RAID arrays have been built
by using the replaced storage controller. This is because RAID configuration information is saved
on both the storage controller and drives.
The failure might cause the controller to stop operating if the controller's boot mode is set to
Stop
on Error
. The server cannot identify the new storage controller and the BIOS displays
Failed
on the
Advanced
>
Driver Health
>
AVAGO EFI SAS Driver
page.
To solve this issue, perform the following tasks:
1.
On the BIOS setup screen, select
Advanced
>
Driver Health
>
AVAGO EFI SAS Driver
, and
press
Enter
.
2.
Select the storage controller, and press
Enter
.
3.
As shown in
, enter
C
or
Y
as prompted.
Figure 7 Identifying a storage controller (1)