16
Figure 21 Selecting View Associated Drives
Configuring hot spare drives
For data security purposes, configure hot spare drives after configuring a RAID array. You can
configure global hot spare drives or dedicated hot spare drives.
NOTE:
•
A hot spare drive can be used only for RAID levels with redundancy.
•
The capacity of a hot spare drive must be equal to or greater than the capacity of the smallest
drive in the RAID array.
•
Only the drive in
Unconfigured Good
state can be configured as a hot spare drive.
Configuring a global hot spare drive
1.
On the storage controller configuration screen as shown in
, select
Drive
Management
and press
Enter
.
Содержание UniServer B5700 G3
Страница 35: ...19 Figure 29 Selecting the RAID volume to be deleted...
Страница 116: ...56 Figure 96 Controller Configuration screen...
Страница 220: ...61 Figure 109 Selecting Main Menu 2 Select Controller Management and press Enter...
Страница 243: ...84 Figure 153 Confirming the operation...
Страница 293: ...50 Figure 89 Clearing completion...
Страница 382: ...21 Figure 27 Storage controller information...
Страница 389: ...7 Figure 8 Identifying a storage controller 2...