15
NOTE:
Deleting logical drives in the middle of a RAID array might cause discontinuous sectors on the
physical drives of this array. As a consequence, the operation might affect the drive read and write
rate and limit the operations on logical drives performed by using RAID array configuration tools. As
a best practice to avoid these problems, delete logical drives from back to front in sequence. If you
delete logical drives in the middle, wait for all the logical drives to enter normal state before
executing any other operations.
To delete a RAID array:
1.
On the storage controller configuration screen as shown in
, select
Array
Configuration
and press
Enter
.
Figure 23 Storage controller configuration screen
2.
On the screen as shown in
, select
Manage Arrays
and press
Enter
.