77
[Sysname-Serial4/1/8:10] fr lmi n393dte 6
fr lmi t392dce
Syntax
fr lmi t392dce
t392-value
undo fr lmi t392dce
View
Interface view
Default level
2: System level
Parameters
t392-value
: Value of T392 at the DCE side. The range of the value is 5 to 30, in seconds.
Description
Use the
fr
lmi t392dce
command to set T392 parameter at the DCE side.
Use the
undo fr
lmi t392dce
command to restore the default.
By default, the parameter value is 15 seconds.
This parameter defines the maximum time for DCE waiting for a Status-Enquiry message.
T392 at the DCE side should be greater than T391 at the DTE side, which is configured by using the
timer
hold
command.
Examples
# Set the frame relay interface Serial 4/1/8:10 to operate in DCE mode and set T392 to 10 seconds.
<Sysname> system-view
[Sysname] interface Serial 4/1/8:10
[Sysname-Serial4/1/8:10] link-protocol fr
[Sysname-Serial4/1/8:10] fr interface-type dce
[Sysname-Serial4/1/8:10] fr lmi t392dce 10
fr lmi type
Syntax
fr lmi type
{
ansi
|
nonstandard
|
q933a
}
undo fr lmi type
View
Interface view
Default level
2: System level
Parameters
ansi
: Standard LMI protocol type of ANSI T1.617 Appendix D.
nonstandard
: Nonstandard compatible LMI protocol type.