5-34
Displaying the operational status of power
supplies
Use the
display power
command to display the operational status of power supplies.
<Sysname> display power
Power 0 Status: Normal
Power 1 Status: Absent
Table5-4 Output description
Field
Description
Power
Number of the power supply.
Status
Power supply state:
•
Normal
—The power supply is operating correctly.
•
Absent
—The power supply is not in position.
•
Abnormal
—The power supply has failed.
Displaying the temperature information of the
firewall
Use the
display environment
command to display the temperature information of the firewall.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit Shutdown-U
pperLimit
inflow 1 26 -5 48 56 NA
NOTE:
Only the F100-A-G3, F100-E-G3, F1000-C-G3, F1000-S-G3, F1000-A-G3, and F1000-E-G3
firewalls support the
display
environment
command.
Table5-5 Output description
Field
Description
Sensor
Temperature sensor:
•
inflow
—Air inlet vent temperature sensor.
•
outflow
—Air outlet vent temperature sensor.
•
hotspot
—Hotspot temperature sensor.
Temperature
Current temperature.
LowerLimit
Low temperature alarm threshold.
Warning-UpperLimit
Warning-level high temperature alarm threshold.
Alarm-UpperLimit
Alarm-level high temperature alarm threshold.
Shutdown-Upperlimit
Shutdown-level high temperature alarm threshold. The firewall automatically