3-17
Connecting the Power Cords
Make sure that the ground wire has been properly connected before powering on the switch.
Table 3-3
Power cord connection methods of the S5500-SI series
Switch module
Power supply mode
Connection method
AC power supply
Connecting the AC Power Cord
S5500-28C-SI
S5500-52C-SI
RPS power supply
Connect RPS power cords of
S5500-28C-SI and S5500-52C-SI
AC power supply
Connecting the AC Power Cord
S5500-28C-PWR-SI
S5500-52C-PWR-SI
RPS power supply
Connecting the RPS Power Cord of
the S5500-28C-PWR-SI and
S5500-52C-PWR-SI
PSR150-A: AC power supply
Connecting the AC Power Cord
S5500-20TP-SI
PSR150-D: -48V DC power supply
Connecting the -48V DC Power Cord
Connecting the AC Power Cord
To connect an AC power cord, follow these steps:
Step1
Wear an ESD-preventive wrist strap, ensure a good skin contact and make sure that the
ESD-preventive wrist strap is properly grounded.
Step2
Install the bail latch to prevent the AC power cord from accidentally falling off. Fix the bail latch into the
holes located at the two sides of the AC power receptacle.
Step3
Pull the bail latch to one side of the AC receptacle on the switch (see in
Figure 3-21
,
Figure 3-23
or
Figure 3-25
).
Step4
Connect one end of the AC power cord to the AC receptacle on the switch (see callout 1 in
Figure 3-22
,
Figure 3-24
or
Figure 3-26
).
Step5
Pull the bail latch to another side to secure the plug to the AC receptacle (see callout 2 in
Figure 3-22
,
Figure 3-24
or
Figure 3-26
).
Step6
Connect the other end of the AC power cord to the external AC power supply system.
Step7
Check whether the system status LED (PWR/SYS) on the front panel of the switch is ON. If the LED is
ON, it shows the power cord is properly connected.