3-6
Figure 3-4 Installing a cable management bracket (S12516R)
(1) Spring tab on the cable management bracket
(2) Align the cable management bracket with the bracket hole
NOTE:
You must press the spring tab while you are removing a cable management bracket.
Installing fabric modules
WARNING!
When you hot swap a fabric module, only one fan tray is operating and it automatically increases
the fan rotation speed and makes louder noise. Take protection measures such as wearing an
earmuff or earplug. In addition, make good preparation before the hot swapping to minimize the
operation time.
CAUTION:
•
When you install a fabric module, avoid damaging the connectors on it.
•
Fan trays cover fabric module slots. Before installing a fan tray, install fabric modules or filler
panels in the fabric module slots the fan tray will cover.
•
To replace or install fabric modules in the slots covered by both fan trays when the device is
operating, do not remove both fan trays at the same time. Remove one fan tray to replace or
install fabric modules in slots covered by the fan tray, and then reinstall the fan tray. You can
remove the other fan tray only after this fan tray operates correctly.
•
To avoid module damage or operation failure, use Type H fabric modules only with Type H
service modules. Type H fabric modules have a character string of
SFH
in their module
identifiers (LSXM2
SFH
16CR1 for example).Type H service modules have a character of
H
in
their module identifiers (LSXM1CGQ36
H
BR1 for example).
The device comes with all fabric module slots empty. Purchase fabric modules and filler panels as
required.