2-4 

Slide rail requirements 

 

IMPORTANT: 

The device is heavy. Install the device at the lowest possible position. 

 

Attach  the  required  slide  rails  to  the  rack  before  you  mount  the  device  in  the  rack.  For  more 

information about attaching slide rails, see the installation guide for the slide rails. 
Before attaching the slide rails, read signs on the slide rails to identify the right and left slide rails 

and their front and rear ends. Mount the front end of the slide rails to the front rack posts. Make sure 

the slide rail installation positions are at the same height on the four rack posts. 

Table 2-2 Slide rail requirements 

Device 
model 

Max. chassis 
weight (full 
configuration) 

Applicable slide rails 

Slide rail model 

Adjustment range 

Occupied 
space 

S12516R 

400 kg (881.85 lb)

LSXM1BSR 

630 mm (24.80 in) to 

900 mm (35.43 in) 

1 U 

S12508R 

220 kg (485.02 lb)

LSXM1BSR 

630 mm (24.80 in) to 

900 mm (35.43 in) 

1 U 

LSTM2KSGD0 

500 mm (19.69 in) to 

800 mm (31.50 in) 

2 U 

S12504R 

120 kg (264.55 lb)

LSVM1BSR10 

630 mm (24.80 in) to 

850 mm (33.46 in) 

N/A 

 

 

NOTE: 

  The LSXM1BSR slide rail kit includes a left slide rail, a right slide rail, and a front plate. When 

attaching the slide rails to the rack, make sure all accessories are correctly installed. 

  Flanges of the LSVM1BSR10 slide rails are at the bottom so the slide rails do not occupy rack 

space. 

 

Installing cage nuts for attaching mounting 

brackets 

Before mounting the chassis in the rack, install cage nuts on the front rack posts for attaching the 

mounting brackets: 

1. 

As shown in 

Figure 2-5

Figure 2-6

and 

Figure 2-7

determine the cage nut installation holes 

and then mark them on the front rack post. 

2. 

Install cage nuts in the marked square holes on the front rack posts. 
For the S12516R and S12508R, cage nuts are not needed for the top two marked square 

holes on the right front rack post. 
For the S12504R, install cage nuts in all the marked square holes. 

Содержание S12500R Series

Страница 1: ...H3C S12500R Ethernet Switch Router Series Installation Quick Start New H3C Technologies Co Ltd http www h3c com Document version 5PW101 20200426...

Страница 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Страница 3: ...cable management brackets 3 5 Installing fabric modules 3 6 Installing a filler panel in a fabric module slot 3 8 Removing a filler panel from a fabric module slot 3 9 Installing fan trays 3 10 Insta...

Страница 4: ...n ESD sign Examining the installation site The device must be used indoors To make sure the device operates correctly and to prolong its service lifetime the installation site must meet the load beari...

Страница 5: ...1 2 Installation tools and equipment No installation tools and equipment are provided with the device Prepare them yourself as required...

Страница 6: ...2 1 2 Installing the device Device dimensions Figure 2 1 S12516R dimensions 1 Fan tray handle 2 Mounting bracket 3 Cable management bracket...

Страница 7: ...able management bracket Figure 2 3 S12504R dimensions with the LSXM104XFAN fan trays 1 Fan tray handle 2 Mounting bracket 3 Cable management bracket Figure 2 4 S12504R dimensions with the LSXM104XFANH...

Страница 8: ...from the rear side of the mounting bracket front ear to the management bracket front end 875 mm 34 45 in from the rear side of the mounting bracket front ear to the fan tray handle at the rear of the...

Страница 9: ...02 lb LSXM1BSR 630 mm 24 80 in to 900 mm 35 43 in 1 U LSTM2KSGD0 500 mm 19 69 in to 800 mm 31 50 in 2 U S12504R 120 kg 264 55 lb LSVM1BSR10 630 mm 24 80 in to 850 mm 33 46 in N A NOTE The LSXM1BSR sl...

Страница 10: ...2 5 Figure 2 5 Installing cage nuts S12516R...

Страница 11: ...2 6 Figure 2 6 Installing cage nuts S12508R Figure 2 7 Installing cage nuts S12504R 1U 2U 4U 2U 1U 2U...

Страница 12: ...device damaging the device or even causing bodily injury To mount the device in the rack 1 Face the rear of the chassis towards the front of the rack 2 Place the device on the slide rails from the fr...

Страница 13: ...t the grounding cable to a grounding strip 1 Unpack the grounding cable The grounding cable provided with the device is compliant with the NEBS standards The two hole grounding lug of the grounding ca...

Страница 14: ...the grounding cable to a grounding strip S12516R 1 Use the grounding screws to attach the two hole grounding lug to the grounding point 2 Grounding sign 3 Grounding strip 4 Grounding post 5 Ring termi...

Страница 15: ...amaging the connectors on the MPU To prevent a filler panel from being drawn into the chassis when fan speed is high use both hands to grasp the filler panel by its two sides during filler panel insta...

Страница 16: ...Installing MPUs for the S12504R The S12504R MPU marks and MPU slot edges are pink marked To install an MPU for the S12504R 1 As shown by callout 1 in Figure 3 2 remove the filler panel from the targe...

Страница 17: ...dules CAUTION To prevent a filler panel from being drawn into the chassis when the fan speed is high use both hands to grasp the filler panel by its two sides during filler panel installation and remo...

Страница 18: ...ing on it upright Push the service module slowly and steadily into the slot along the guide rails Avoid touching other components in the chassis 3 As shown by callout 2 in Figure 3 3 pull the ejector...

Страница 19: ...asten the captive screws on the service module Installing cable management brackets The cable management brackets are installed on the two sides of the service module slots As a best practice install...

Страница 20: ...s Before installing a fan tray install fabric modules or filler panels in the fabric module slots the fan tray will cover To replace or install fabric modules in the slots covered by both fan trays wh...

Страница 21: ...t it into the slot along the guide rails See callout 1 in Figure 3 6 Keep the module parallel to the slot to avoid touching other components in the chassis 4 As shown by callout 2 in Figure 3 6 contin...

Страница 22: ...the filler panel with the side marked Up facing up Hold the filler panel front panel near the ejector levers with one hand and support its bottom with the other Place the filler panel bottom gently on...

Страница 23: ...ller panel from a fabric module slot 1 As shown by callout 1 in Figure 3 8 loosen the captive screws on the ejector levers 2 As shown by callout 2 in Figure 3 8 rotate outward the ejector levers Then...

Страница 24: ...aring an earmuff or earplug In addition make good preparation before the hot swapping to minimize the operation time IMPORTANT Fan trays cover fabric module slots Before you install a fan tray install...

Страница 25: ...lot 2 Holding the upper fan tray handle with one hand and the lower fan tray handle with the other hand insert the fan tray into the slot Keep the fan tray as straight as possible To install a fan tra...

Страница 26: ...with the positioning hole in the chassis 2 Insert the fan tray into the chassis 3 Fasten the captive screws on the fan tray Installing power modules The power module slots are located at the two side...

Страница 27: ...breaker for it is turned off CAUTION Before powering on the device make sure the fan trays are installed correctly Connecting an AC power cord 1 Connect the AC power cord connector into the AC input...

Страница 28: ...R Connecting a DC power cord 1 Connect the DC power cord connector to the DC input receptacle on the power module 2 Fasten the screw on the connector to secure the DC power cord in place 3 Connect the...

Страница 29: ...emove the dust plug from the SFP SFP QSFP QSFP28 module if you are not to connect an optical fiber to the module Before you install an SFP SFP QSFP QSFP28 module remove the optical fiber if any from i...

Страница 30: ...meter The cables are hot swappable Use SFP DAC cables to connect SFP ports QSFP DAC cables to connect QSFP ports QSFP28 DAC cables to connect QSFP28 ports and QSFP to SFP DAC cables to connect QSFP an...

Страница 31: ...assis front edges on its two sides As a best practice route the cables from the left half of the chassis through the left cable management bracket and the cables from the right half of the chassis thr...

Страница 32: ...female connector of the console cable to the serial port of the PC 2 Plug the RJ 45 connector of the console cable to the console port of the device Figure 5 1 Connecting a terminal to the console po...

Страница 33: ...ting Normal Extended BootWare The Extended BootWare is self decompressing Done System image is starting Line aux0 is available Press ENTER to get started Press Enter at the prompt When the prompt Sysn...

Отзывы: