1-3
z
Hold timer
Related commands:
garp timer
,
garp timer leaveall
.
Examples
# Display the settings of the GARP timers on port Ethernet1/0/1.
<Sysname> display garp timer interface Ethernet 1/0/1
GARP timers on port Ethernet1/0/1
Garp Join Time : 20 centiseconds
Garp Leave Time : 60 centiseconds
Garp LeaveAll Time : 1000 centiseconds
Garp Hold Time : 10 centiseconds
garp timer
Syntax
garp timer
{
hold
|
join
|
leave
}
timer-value
undo garp timer
{
hold
|
join
|
leave
}
View
Ethernet port view
Parameters
hold
: Sets the GARP Hold timer.
join
: Sets the GARP Join timer.
leave
: Sets the GARP Leave timer.
timer-value
: Timeout time (in centiseconds) of the GARP timer (Hold, Join or Leave) to be set.
Description
Use the
garp timer
command to set a GARP timer (that is, the Hold timer, the Join timer, or the Leaver
timer) for an Ethernet port.
Use the
undo garp timer
command to restore the default setting of a GARP timer.
By default, the Hold, Join, and Leave timers are set to 10, 20, and 60 centiseconds.
Note that:
z
The setting of each timer must be a multiple of 5 (in centiseconds).
z
The timeout ranges of the timers vary depending on the timeout values you set for other timers. If
you want to set the timeout time of a timer to a value out of the current range, you can set the
timeout time of the associated timer to another value to change the timeout range of this timer.
The following table describes the relations between the timers:
Содержание H3C S3600 Series
Страница 502: ...2 3 System View return to User View with Ctrl Z Sysname dot1x url http 192 168 19 23 ...
Страница 507: ...3 5 Sysname habp timer 50 ...
Страница 650: ...iii display bootp client 5 3 ip address bootp alloc 5 4 ...
Страница 1085: ...ii schedule reboot delay 3 18 schedule reboot regularity 3 19 system monitor enable 3 20 update fabric 3 21 xmodem get 3 22 ...