1-18
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] flow-control
flow interval
Syntax
flow-interval interval
undo flow-interval
View
Ethernet port view
Parameters
Interval
: Interval (in seconds) to perform statistics on port information. This argument ranges from 5 to
300 (in step of 5) and is 300 by default.
Description
Use the
flow-interval
command to set the interval to perform statistics on port information.
Use the
undo flow-interval
command to restore the default interval.
By default, this interval is 300 seconds.
When you use the
display interface interface-type interface-number
command to display the
information of a port, the system performs statistical analysis on the traffic flow passing through the port
during the specified interval and displays the average rates in the interval. For example, if you set the
interval to 100 seconds, the displayed information is as follows:
Last 100 seconds input: 0 packets/sec 0 bytes/sec
Last 100 seconds output: 0 packets/sec 0 bytes/sec
Related commands:
display interface
.
Examples
# Set the interval to perform statistics on the Ethernet 1/0/1 port to 100 seconds.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] interface ethernet 1/0/1
[Sysname-Ethernet1/0/1] flow-interval 100
giant-frame statistics enable
Syntax
giant-frame statistics enable
undo giant-frame statistics enable
View
System view
Parameters
None
Содержание H3C S3600 Series
Страница 502: ...2 3 System View return to User View with Ctrl Z Sysname dot1x url http 192 168 19 23 ...
Страница 507: ...3 5 Sysname habp timer 50 ...
Страница 650: ...iii display bootp client 5 3 ip address bootp alloc 5 4 ...
Страница 1085: ...ii schedule reboot delay 3 18 schedule reboot regularity 3 19 system monitor enable 3 20 update fabric 3 21 xmodem get 3 22 ...