operation
file: n:\article\cos14310m5-v1_08hpc-en\20150130_cos14310m5-v1.08hpc-en_instructions_for_use_h-p-cosmos_treadmill.doc
© 2015 h/p/cosmos sports & medical gmbh author: fh [email protected] created 30.01.2015 printed 30.01.2015 page: 30 of 216
[08]
Switch on the running machine by using the white
key (until 2003 green "ON" or "I" key) at the
FrontTerminal. For some models built before the year
12/2007 the location of the ON-/OFF-key may also be
the UserTerminal.
The indicator light within the key (push button) is
illuminated.
If the indicator does not flash up, please check the
power supply, the expulsion fuse and the emergency
stop.
Devices for sports and fitness before manufacturing date 12/2007:
The running machine can be switched on directly at the expulsion fuse on the FrontTerminal (frontal section below
the hood) to the setting "stand-by mode".
If the emergency stop has been activated, a flashing notice „PULL STOP“ appears on the display.
Expulsion fuse and
main switch 2- or 3-pole
ON / OFF button
with control lamp
ON / OFF button
until 2003
5.3.3
Switch on procedure model range 200/75 up to 300/125 (venus / saturn)
no.
Illustration
Description
[01]
Plug the power cord of the running machine directly
into the CEE wall socket.
Only the model saturn 450/300rs has a permanent
connection to the mains and no power plug.
N
If the running machine is at an angle of elevation > 0 when switched on, it will automatically
move to the position zero (display elevation „INIT“). Please ensure that while lowering the
elevation no harm is done to persons or objects under the running machine.
N
Plug the running machines directly into the wall socket. (Model 450/300 has permanent
connection and no power plug). Each running machine should be connected to a separate
circuit. Mark the socket with the name and serial number of the running machine.
N
The use of extension cables or multiple plug sockets is not allowed.
N
Electrical devices with mains connections must neither be used in wet and humid areas
(e.g. swimming pools, saunas, etc.) nor in environmental chambers.