trouble shooting
file: n:\article\cos14310m5-v1_08hpc-en\20150130_cos14310m5-v1.08hpc-en_instructions_for_use_h-p-cosmos_treadmill.doc
© 2015 h/p/cosmos sports & medical gmbh author: fh [email protected] created 30.01.2015 printed 30.01.2015 page: 135 of 216
9
Trouble shooting
In case of a detected and/or assumed malfunction and/or defects or unreadable safety warning label,
disengage the device immediately and mark it as such. Furthermore, secure the device against further
operation and inform the supplier and authorised service personnel in writing.
See OP40 in chapter 0 entitled “
Optional settings: User Options: With OP 41 ... 44 you can also lock separate modes (manual, profile,
cardio, test).
9.1
Device cannot be powered on
If the indicator of the power on push button does not flash up, please check the power supply, the device protection
switch and the emergency stop.
In case the TouchPanel PC does not boot up it
can be switched on manually. Therefore the
external control unit has to be opened in order
to reach the power switch at the rear of the
TouchPanel PC. Opening of the device must
only be performed by authorized technicians.
9.2
Mechanical noise problems
If knocking or rattling noises are heard during training, please check if the machine has a firm stand and follow exactly
the advice given in the chapter 7.4.5 "Mechanical installation". Most often false adjustment of the levelling sockets
(adjustable "feet") at the rear of the running machine is responsible for the knocking sound.
9.3
Running belt adjustment problems
If the tension of the running belt is not correct, it is difficult to keep the position of the belt centred. The belt should be re-
adjusted every time it is used in reverse direction mode. Check and follow exactly the advice in the chapter 8.5 entitled
"Control and tightening of the running belt"
At the saturn 450/300 the belt will be adjusted automatically. Load cells at the left and right side of the deviation shaft
control the tension of the belt.