ELECTRO FREEZE Soft Serve Model GEN-2080
30
185240
8.3 Cleaning Instructions
— Soft Serve (continued)
d. The air bleed plug O-ring
grooves.
e. The beater shaft and the
scraper blade pin holes as shown in figure
8-9.
3. After all parts are washed, rinse
and then place them in the sanitizing
solution. For proper sanitizing, the
parts must remain fully immersed in the
sanitizer for 5 minutes. Allow parts to air-
dry after sanitizing.
Important:
Do not leave parts in sanitizing
solution for more than 15 minutes.
3. After all parts are washed, rinse
and place in the sanitizing solution.
Brush the inside of all mix transfer hoses
with sanitizer. For proper sanitizing, the
parts must remain fully immersed in the
sanitizer for 5 minutes. Allow parts to air-
dry after sanitizing.
4. Using a warm mild dish detergent
solution thoroughly brush:
a. the mix feed tubes from the
cabinet to the cylinders (figure 8-10)
b. the inside of the cylinders
making certain to clean the back walls,
and the inside of the drain tube as shown
in figure 8-11 (dip the brush in the dish
detergent solution and force into the drain
tube until it stops - repeat until clean).
5. Wash the drip tray and insert in
the warm dish detergent solution and
rinse with clear water.
6. Wash the outside of the freezer
and the inside of the cabinet with the dish
detergent solution. Rinse with clear water.
Figure 8-9 Clean Scraper Blade Pin Holes
Figure 8-11 Brush inside of cylinders and
drain tubes.
Figure 8-10 Brush inside of cylinder mix
feed tubes.