ELECTRO FREEZE Soft Serve Model GEN-2080
18
185240
L1
2
3
4
5
6 7 8
9
10
2
4
L2
R1
R2
1
LEFT
RIGHT
OFF
OFF
6 Operator Controls
Figure 6-1
The following paragraphs describe the
operator controls. Refer to Fig. 5-1 for
numbered items in description. Note
the left side controls operates the left
side cylinder. Operation for right side
controls is the same. The display
window has three levels of display:
Operators Menu, Technician Menu. The
last menu is restricted and reserved for
use by qualified personnel.
CAUTION
Test operation of the head
switch prior to placing
the freezer in service.
See Section 11, Routine
Maintenance, Monthly.
NOTE: The dispense head must be in
place before the freezer will operate.
1. Function Buttons
(Four)
Pressing any of these buttons will activate the icon directly above in the display screen.
Left side (L1 & L2), Right Side (R1& R2).
2.
OFF Key
When this symbol is pressed, the left side of unit will shut off. The beater motor and
compressor will not operate.
3. Navigation Pad
(Up/Down = Cabinet ON/OFF)
Used to navigate the menu structure. Up/Down arrows are used to turn the cabinet
on/off when both cylinders are off. Used by technicians for programming and setting
changes. See Troubleshooting section for Operator accessible controls.
4.
Freeze Symbol
When this symbol is pressed, the unit will enter the automatic freeze mode. Both
the hopper and cylinder compressors will energize to refrigerate product to settings
in program. Use this button for DAY mode operation to maintain product in “ready
to serve” state.