- 41 -
The general operations are as below:
▲▼
◄►
Press these buttons to select the items.
MODE
=> Format/Clear
Press this button to format/clear the HDDs as described in
Section 6.6.1
.
ESC
Press this button to escape from this screen, and return to Setup Menu display. If the Save
dialog is shown, press
ENTER
to exit and save,
ESC
to exit without saving.
Following is a brief description for each item and its specific operations:
Size (GB)
– the total HDD storage in GB (Giga-Byte) for Alarm Record and Normal Record
respectively. This item is just for information. Please refer to
Section 6.6.1
for more detailed
information and setup of each individual HDD.
Auto Overwrite
– automatic overwrite of the recorded video/audio from HDD#1 when the
Alarm/Normal Record disk drive capacity reaches the end of the last HDD. If Auto Overwrite
is disabled and the Alarm/Normal Record disk drive capacity reaches the end, the system will
not overwrite the recorded video/audio, and hence not record Alarm/Normal video/audio, until
the user presses the
Alarm Reset
button. Press
ENTER
or
+/-
to check/uncheck this item.
The default setting is “
ˇ
” - checked.
HDD Full Action
– actions when Alarm/Normal Record disk drive capacity reaches the end of
the last HDD. Press
ENTER
or
+/-
to check/uncheck this item. The default setting is “
ˇ
” -
checked.
Duration
– response duration to define at most how long (in seconds) the Alarm Out relay and
the Buzzer will keep being triggered after the corresponding partition, Alarm Record or Normal
Record, is full. Press
+/-
buttons to adjust the value (3-60 seconds, discrete).
Alarm Out
– to define which Alarm Output will be triggered when the corresponding partition,
Alarm Record or Normal Record, is full. Press
+/-
buttons to select none (N/A) or one of the
Alarm Outputs (1-2).
Buzzer
– to activate the internal Buzzer or not when the corresponding partition, Alarm Record
or Normal Record, is full. Press
ENTER
or
+/-
to check/uncheck this item. The default
setting is “
ˇ
” - checked.
Log
– to log to event logs or not. Press
ENTER
or
+/-
to check/uncheck this item. The
default setting is “
ˇ
” - checked.
– to send the event e-mail to remote station or not. The e-mail will be sent to the
predefined receivers when the event is triggered. Press
ENTER
or
+/-
to check/uncheck this
item. The default setting is “
–
” - unchecked.
SCW-7704 User Manual
SCW-7704 User Manual