5
Sulphated batteries
These batteries left without servicing for too long may, sometime, partially recharged on “Manual” mode. This
type of battery can be recognised, when under charge, the ammeter remains around 0.
In this case, put the selector on the fastest charging current and monitor the charger until you see the ammeter
needle raises from 0. Then, start an automatic charging process. In case it stays on 0 after 5 hours, the battery is
out of order.
IV - ADVISES AND WARNINGS
• Your charger must be connected to earth. Otherwise, serious danger of electrical chock!
• At the end of the charging process you may have emission of explosive gas by the battery (boiling). Avoid any
spark or flame in the area.
• Do not attempt to charge non rechargeable batteries.
• In case of wear or damage to the mains cable, please return the charger to your dealer for repair.
• Your charger complies with the EMC Directive (decree 92-587) and can be used in domestic premises. The user
remains liable to recognize the environment and avoid any use close to sensitive apparatus.
V - DECLARATION OF COMPLIANCE
GYS certifies that the product described on this manual is manufactured in compliance with the requirements
of the following European directives:
- Low Voltage Directive: 2006/95/EC - 12/12/2006 (amended by 93/68/EEC)
- EMC Directive: 2004/108/EC, 15/12/2004 (amended by 92/31/EEC, 93/68/EEC, 91/263/EEC, 93/97/EEC),
It therefore complies with the following harmonized standards: EN60335-1 - EN60335-2-29 – EN55014-1 -
EN55014-2 – EN61000-3-2– EN61000-3-3 – EN62233.